Skip to main content

ETHNOS_APP

Home • Search • Journals • List 0

To evaluate the effects of lubricating eye drops on the repeatability of keratometry (K) measurements in patients presenting for cataract surgery

-

Bibliographic Data

ID15792384
AuthorsDhruv Goyal (Jawaharlal Nehru Medical College, corresponding author), B K Bhagyajyothi, B K Bhagyajyothi Dr B K Bhagyajyothi, Krutika Thorat, Krutika Thorat Dr Krutika Thorat, Arvind L Tenagi (0000-0003-3851-4093, Jawaharlal Nehru Medical College), Arvind L Tenagi Dr Arvind L Tenagi, Mitali Mangoli, Mitali Mangoli Dr Mitali Mangoli
Year2025
Volume9
Issue2
Publication date2025-05-04
Peer ReviewedYes
Open AccessYes
TypeARTICLE
VenueInternational Journal of Health Sciences (JOURNAL)
Journal identifiersISSN: 2550-696X • E-ISSN: 2550-6978
PublisherUniversidad Tecnica de Manabi (PUBLISHER • EC)
DOI10.53730/ijhs.v9n2.15634
OpenAlexW4410062884
LanguageEN
References cited19

Purpose – To evaluate the impact of lubricating eye drops on the repeatability of keratometry (K) measurements in cataract surgery patients. Design – Prospective, comparative, hospital-based study. Method – Keratometry was performed using an autorefractometer. At Visit 1, baseline K readings were taken twice before instilling drops. After instillation, K readings were recorded at 30 seconds and 2 minutes. Tear Break-Up Time (TBUT) was measured to classify patients into normal and dry eye groups. A second set of readings was taken the following morning. At Visit 2, one week postoperatively, a third set of K1 and K2 readings was recorded. Result – Variations in K1 and K2 readings were analyzed across time points and between tear film groups. In the dry eye group, significant changes in K1 were observed across intervals (p < 0.0001). Significant differences in K1 were also found between normal and dry eyes at 30 seconds and 2 minutes post-instillation. For K2, notable differences occurred in both groups, particularly between pre- and postoperative readings and all intervals in the dry eye group. Conclusion – Lubricating drops significantly affect keratometry, especially in dry eyes. Waiting over 5 minutes post-instillation is advised before taking measurements

Cataract surgery · Cornea · Keratometer · Repeatability · Statistics · Corneal surgery and disorders · Glaucoma and retinal disorders · Mathematics · Medicine · Ocular Surface and Contact Lens · Ophthalmology · Optometry · Surgery