To evaluate the effects of lubricating eye drops on the repeatability of keratometry (K) measurements in patients presenting for cataract surgery
-
Bibliographic Data
| ID | 15792384 |
|---|---|
| Authors | Dhruv Goyal (Jawaharlal Nehru Medical College, corresponding author), B K Bhagyajyothi, B K Bhagyajyothi Dr B K Bhagyajyothi, Krutika Thorat, Krutika Thorat Dr Krutika Thorat, Arvind L Tenagi (0000-0003-3851-4093, Jawaharlal Nehru Medical College), Arvind L Tenagi Dr Arvind L Tenagi, Mitali Mangoli, Mitali Mangoli Dr Mitali Mangoli |
| Year | 2025 |
| Volume | 9 |
| Issue | 2 |
| Publication date | 2025-05-04 |
| Peer Reviewed | Yes |
| Open Access | Yes |
| Type | ARTICLE |
| Venue | International Journal of Health Sciences (JOURNAL) |
| Journal identifiers | ISSN: 2550-696X • E-ISSN: 2550-6978 |
| Publisher | Universidad Tecnica de Manabi (PUBLISHER • EC) |
| DOI | 10.53730/ijhs.v9n2.15634 |
| OpenAlex | W4410062884 |
| Language | EN |
| References cited | 19 |
Purpose – To evaluate the impact of lubricating eye drops on the repeatability of keratometry (K) measurements in cataract surgery patients. Design – Prospective, comparative, hospital-based study. Method – Keratometry was performed using an autorefractometer. At Visit 1, baseline K readings were taken twice before instilling drops. After instillation, K readings were recorded at 30 seconds and 2 minutes. Tear Break-Up Time (TBUT) was measured to classify patients into normal and dry eye groups. A second set of readings was taken the following morning. At Visit 2, one week postoperatively, a third set of K1 and K2 readings was recorded. Result – Variations in K1 and K2 readings were analyzed across time points and between tear film groups. In the dry eye group, significant changes in K1 were observed across intervals (p < 0.0001). Significant differences in K1 were also found between normal and dry eyes at 30 seconds and 2 minutes post-instillation. For K2, notable differences occurred in both groups, particularly between pre- and postoperative readings and all intervals in the dry eye group. Conclusion – Lubricating drops significantly affect keratometry, especially in dry eyes. Waiting over 5 minutes post-instillation is advised before taking measurements
Cataract surgery · Cornea · Keratometer · Repeatability · Statistics · Corneal surgery and disorders · Glaucoma and retinal disorders · Mathematics · Medicine · Ocular Surface and Contact Lens · Ophthalmology · Optometry · Surgery
| Citation velocity | historical |
|---|---|
| Highly cited | No |