Improvements of stratified micro-environments on the satisfaction of individual thermal preferences and energy-efficiency

Datos Bibliográficos

ID21228909
AutoresXue Tian (0000-0001-6140-4162, City University of Hong Kong), Yuchun Zhang (0000-0001-5488-2502, City University of Hong Kong), Zhang Lin (0000-0002-8421-879X, City University of Hong Kong, autor de correspondencia)
Año2023
Volumen96
Páginas104683
Fecha de publicación2023-09-01
Open AccessSí
TipoARTICLE
RevistaSustainable Cities and Society (JOURNAL)
Identificadores de la revistaISSN: 2210-6707 • E-ISSN: 2210-6715
EditorialElsevier BV (PUBLISHER)
DOI10.1016/j.scs.2023.104683
OpenAlexW4378591379
IdiomaEN
Citas recibidas1
Referencias citadas55

Stratified micro-environments (SME) aim to simultaneously provide various thermal comfort levels in a shared space to satisfy individual needs at different positions. The first objective of this study is to find out the quantitative improvements made by applying the SME against stratum ventilation (SV), mixing ventilation (MV), and displacement ventilation (DV). Thermal comfort indices, including predicted mean vote (PMV) and draft rate (DR), are used to quantify individual preferences. The PMV 1 and PMV 2 represent overall thermal sensation levels at Positions 1 and 2, set in a simulated small office, respectively. The DRs are named in the same rule. Results show that the |PMV 1 - PMV 2 | value under SV, MV, and DV only reaches 24.7%, 4.4%, and 4.6% of that under the SME on average, and the |DR 1 -DR 2 | value reaches 24.9%, 10.6%, and 7.0%. Later, the PMV prediction model for non-free-jet conditions is developed by multiple linear regression method. With practical constraints attached, the scope for the SME operation is identified. The maximum |PMV 1 - PMV 2 | value is 1.8; for DR, it is 24.9%. Only 9.9% of the PMV combinations and 3.8% of the DR combinations under the SME can be satisfied by total volume ventilation (TVV). Lastly, a normal distribution of PMV preference of [-0.5, 0.5] consisting of 40 individuals is utilized as a case study. Over 85% preferences are better satisfied by the SME than TVV, accompanied by an energy-saving rate of 55%-95% than MV

Architectural engineering · Displacement ventilation · Geography · Meteorology · Preference · Simulation · Statistics · Thermal · Thermal comfort · Thermal sensation · Building Energy and Comfort Optimization · Computer Science · Engineering · Environmental Science · Mathematics · Urban Heat Island Mitigation · Wind and Air Flow Studies · Mechanical Engineering

  • Investigating the effect of lower body local radiant warming on occupant thermal comfort in battery electric vehicles during cold conditions

    Open Access•Gineesh Gopi, Seong Eun Yoon et al.•Sustainable Cities and Society•2024

  • Insights on critical parameters and conditions for personalized ventilation

    Open Access•Zhiqiang Zhai, Ian Dominic Metzger et al.•Sustainable Cities and Society•2019

  • Experimental study of local thermal comfort and ventilation performance for mixing, displacement and stratum ventilation in an office

    Open Access•Xue Tian, Bozheng Li et al.•Sustainable Cities and Society•2019

  • Evaluation of sidewall air supply with the stratified indoor environment in a consultation room

    Open Access•Xue Tian, Yong Cheng et al.•Sustainable Cities and Society•2021

  • Numerical comparison of exhaled particle dispersion under different air distributions for winter heating

    Open Access•Teng Li, Emmanuel A Essah et al.•Sustainable Cities and Society•2023

  • Influence of design parameters on the night ventilation performance in office buildings based on sensitivity analysis

    Open Access•Rui Guo, Yue Hu et al.•Sustainable Cities and Society•2019

Citas por año0,5
Intervalo de citas2024 - 2024 (1)
Altamente citadoNo

Herramientas

Abrir DOIOpen Access
Ethnos_APP • Proyecto Open Source • Licencia MIT • Frontend v2.0.0 • Privacidad y Cookies • Documentación de la API: api.ethnos.app/docs • Código de la API: GitHub • DOI: 10.5281/zenodo.17049435 • Código del Frontend: GitHub • DOI: 10.5281/zenodo.17050053 • cruz.rio.br • Expectantes Misericordiae