Three-Dimensional Analysis of Hydroelectric Power Station
This paper decribes the details of finding stresses in a three-dimensional model of a hydroelectric powerhouse subjected to static generator load. In order to locate critical zones, the six components of Cartesian stresses were obtained at about 12,000 points. An attempt to explain the structural behavior of a power station under the load has been made. It has been shown that none of the two-dimensional theories prevalent for the design of power …
Stresses in Concrete Around Spiral Case
The concrete around the spiral case of a hydroelectric power station has such a complex shape that determination of actual stress distribution and explanation of its structural behavior is very difficult. This paper reports the results of original research work done on three-dimensional analysis of such a structure. Photoelastic technique has been employed to determine the six components of stress at 2,700 points due to the static generator load.…
No prominent works on this page.
Three-Dimensional Analysis of Hydroelectric Power Station
This paper decribes the details of finding stresses in a three-dimensional model of a hydroelectric powerhouse subjected to static generator load. In order to locate critical zones, the six components of Cartesian stresses were obtained at about 12,000 points. An attempt to explain the structural behavior of a power station under the load has been made. It has been shown that none of the two-dimensional theories prevalent for the design of power …
Stresses in Concrete Around Spiral Case
The concrete around the spiral case of a hydroelectric power station has such a complex shape that determination of actual stress distribution and explanation of its structural behavior is very difficult. This paper reports the results of original research work done on three-dimensional analysis of such a structure. Photoelastic technique has been employed to determine the six components of stress at 2,700 points due to the static generator load.…
Dam Engineering and Safety (2 works) · Engineering (2 works) · Generator (circuit theory) (2 works) · Hydroelectricity (2 works) · Physics (2 works) · Power (physics) (2 works) · Structural engineering (2 works) · Cartesian coordinate system (1 work) · Computer Science (1 work) · Electrical engineering (1 work)