Michel Jaudon
Biographic Data
| ID | 5599599 |
|---|---|
| NAME | Michel Jaudon |
| GIVEN NAMES | Michel |
| FAMILY NAME | Jaudon |
| SIGNATURE | JAUDON M |
| VERIFIED | No |
| TOTAL WORKS | 2 |
| TOTAL CITATIONS | 3 |
| WORKS AS AUTHOR | 2 |
| WORKS AS EDITOR | 0 |
| FIRST PUBLICATION YEAR | 2022 |
| LATEST PUBLICATION YEAR | 2024 |
| H-INDEX | 1 |
Radiocarbon Dating on Echo Micadas, Lsce, Gif-Sur-Yvette, France
The Laboratoire des Sciences du Climat et de l’Environnement (LSCE) has operated a radiocarbon dating laboratory for almost 70 years. It has evolved from a traditional ß-decay counting to an accelerator mass spectrometry facility. In 2015, the LSCE received a major upgrade with the installation of a MICADAS. This evolution required adjustments in sample preparation to match the new capability to date samples as small as a few tens of μgC. We summ…
Experiments at Modane Underground Laboratory or the Swan Song of Radiocarbon Ss-Counting by Gas Proportional Counter
In 1991, a 14 C ß-counting installation with four proportional CO 2 gas counters was tested at the Modane underground laboratory, 1700 m below the summit of Pointe du Fréjus, reducing the muon flux to 4 muons per square meter and per day. With cosmic radiation attenuated by a factor of 2.10 6 , the background level of the counters was reduced by 65 to 85% while its variability was reduced by a factor of 30–80 depending on the type of counter. The…
Radiocarbon Dating on Echo Micadas, Lsce, Gif-Sur-Yvette, France
The Laboratoire des Sciences du Climat et de l’Environnement (LSCE) has operated a radiocarbon dating laboratory for almost 70 years. It has evolved from a traditional ß-decay counting to an accelerator mass spectrometry facility. In 2015, the LSCE received a major upgrade with the installation of a MICADAS. This evolution required adjustments in sample preparation to match the new capability to date samples as small as a few tens of μgC. We summ…
Experiments at Modane Underground Laboratory or the Swan Song of Radiocarbon Ss-Counting by Gas Proportional Counter
In 1991, a 14 C ß-counting installation with four proportional CO 2 gas counters was tested at the Modane underground laboratory, 1700 m below the summit of Pointe du Fréjus, reducing the muon flux to 4 muons per square meter and per day. With cosmic radiation attenuated by a factor of 2.10 6 , the background level of the counters was reduced by 65 to 85% while its variability was reduced by a factor of 30–80 depending on the type of counter. The…
Experiments at Modane Underground Laboratory or the Swan Song of Radiocarbon Ss-Counting by Gas Proportional Counter
In 1991, a 14 C ß-counting installation with four proportional CO 2 gas counters was tested at the Modane underground laboratory, 1700 m below the summit of Pointe du Fréjus, reducing the muon flux to 4 muons per square meter and per day. With cosmic radiation attenuated by a factor of 2.10 6 , the background level of the counters was reduced by 65 to 85% while its variability was reduced by a factor of 30–80 depending on the type of counter. The…
Radiocarbon Dating on Echo Micadas, Lsce, Gif-Sur-Yvette, France
The Laboratoire des Sciences du Climat et de l’Environnement (LSCE) has operated a radiocarbon dating laboratory for almost 70 years. It has evolved from a traditional ß-decay counting to an accelerator mass spectrometry facility. In 2015, the LSCE received a major upgrade with the installation of a MICADAS. This evolution required adjustments in sample preparation to match the new capability to date samples as small as a few tens of μgC. We summ…
Chemistry (2 works) · Environmental Science (2 works) · Geology (2 works) · Nuclear physics (2 works) · Physics (2 works) · Radiocarbon dating (2 works) · Radiochemistry (2 works) · Radionuclide (2 works) · Accelerator mass spectrometry (1 work) · Archaeology (1 work)