Bernhard Schwaberger
Biographic Data
| ID | 7605478 |
|---|---|
| NAME | Bernhard Schwaberger |
| GIVEN NAMES | Bernhard |
| FAMILY NAME | Schwaberger |
| SIGNATURE | SCHWABERGER B |
| AFFILIATIONS | Medical University of Graz |
| ORCID | 0000-0001-5499-3712 |
| VERIFIED | Yes |
| TOTAL WORKS | 7 |
| TOTAL CITATIONS | 0 |
| AUTHOR COUNT | 7 |
| EDITOR COUNT | 0 |
| FIRST PUBLICATION YEAR | 2020 |
| LATEST PUBLICATION YEAR | 2023 |
| H-INDEX | 0 |
Telesimulation for the Training of Medical Students in Neonatal Resuscitation
Background: Telesimulation may be an alternative to face-to-face simulation-based training. Therefore, we investigated the effect of a single telesimulation training in inexperienced providers. Methods: First-year medical students were recruited for this prospective observational study. Participants received a low-fidelity mannequin and medical equipment for training purposes. The one-hour telesimulation session was delivered by an experienced tr…
PFOE or pFTOE as an Early Marker for Impaired Peripheral Microcirculation in Neonates
The higher pFOE compared to pFTOE suggests a higher potential of pFOE to detect impaired microcirculation, especially when oxygen extraction is elevated
Cardiac Output and Cerebral Oxygenation in Term Neonates during Neonatal Transition
The immediate transition from foetus to neonate includes substantial changes, especially concerning the cardiovascular system. Furthermore, the brain is one of the most vulnerable organs to hypoxia during this period. According to current guidelines for postnatal stabilization, the recommended parameters for monitoring are heart rate (HR) and arterial oxygen saturation (SpO 2 ). Recently, there is a growing interest in advanced monitoring of the …
In Newborn Infants a New Intubation Method May Reduce the Number of Intubation Attempts
Severe desaturation or bradycardia often occur during neonatal endotracheal intubation. Using continuous gas flow through the endotracheal tube might reduce the incidence of these events. We hypothesized that continuous gas flow through the endotracheal tube during nasotracheal intubation compared to standard nasotracheal intubation will reduce the number of intubation attempts in newborn infants. In a randomized controlled pilot study, neonates …
Successful Postnatal Cardiopulmonary Resuscitation Due to Defibrillation
An asphyxiated term neonate required postnatal resuscitation. After six minutes of cardio-pulmonary resuscitation (CPR) and two doses of epinephrine, spontaneous circulation returned, but was shortly followed by ventricular fibrillation. CPR and administration of magnesium, calcium gluconate, and sodium bicarbonate did not improve the neonate’s condition. A counter shock of five Joule was delivered and the cardiac rhythm immediately converted to …
The Use of a Disposable Umbilical Clamp to Secure an Umbilical Venous Catheter in Neonatal Emergencies—An Experimental Feasibility Study
Recent guidelines recommend the umbilical venous catheter (UVC) as the optimal vascular access method during neonatal resuscitation. In emergencies the UVC securement may be challenging and time-consuming. This experimental study was designed to test the feasibility of new concepts for the UVC securement. Umbilical cord remnants were catheterized with peripheral catheters and secured with disposable umbilical clamps. Three different securement te…
Association between Regional Tissue Oxygenation and Body Temperature in Term and Preterm Infants Born by Caesarean Section
Body temperature (BT) management remains a challenge in neonatal intensive care, especially during resuscitation after birth. Our aim is to analyze whether there is an association between the BT and cerebral and peripheral tissue oxygen saturation (crSO 2 /cTOI and prSO 2 ), arterial oxygen saturation (SpO 2 ), and heart rate (HR). The secondary outcome parameters of five prospective observational studies are analyzed. We include preterm and term…
No prominent works on this page.
Association between Regional Tissue Oxygenation and Body Temperature in Term and Preterm Infants Born by Caesarean Section
Body temperature (BT) management remains a challenge in neonatal intensive care, especially during resuscitation after birth. Our aim is to analyze whether there is an association between the BT and cerebral and peripheral tissue oxygen saturation (crSO 2 /cTOI and prSO 2 ), arterial oxygen saturation (SpO 2 ), and heart rate (HR). The secondary outcome parameters of five prospective observational studies are analyzed. We include preterm and term…
Cardiac Output and Cerebral Oxygenation in Term Neonates during Neonatal Transition
The immediate transition from foetus to neonate includes substantial changes, especially concerning the cardiovascular system. Furthermore, the brain is one of the most vulnerable organs to hypoxia during this period. According to current guidelines for postnatal stabilization, the recommended parameters for monitoring are heart rate (HR) and arterial oxygen saturation (SpO 2 ). Recently, there is a growing interest in advanced monitoring of the …
In Newborn Infants a New Intubation Method May Reduce the Number of Intubation Attempts
Severe desaturation or bradycardia often occur during neonatal endotracheal intubation. Using continuous gas flow through the endotracheal tube might reduce the incidence of these events. We hypothesized that continuous gas flow through the endotracheal tube during nasotracheal intubation compared to standard nasotracheal intubation will reduce the number of intubation attempts in newborn infants. In a randomized controlled pilot study, neonates …
Successful Postnatal Cardiopulmonary Resuscitation Due to Defibrillation
An asphyxiated term neonate required postnatal resuscitation. After six minutes of cardio-pulmonary resuscitation (CPR) and two doses of epinephrine, spontaneous circulation returned, but was shortly followed by ventricular fibrillation. CPR and administration of magnesium, calcium gluconate, and sodium bicarbonate did not improve the neonate’s condition. A counter shock of five Joule was delivered and the cardiac rhythm immediately converted to …
The Use of a Disposable Umbilical Clamp to Secure an Umbilical Venous Catheter in Neonatal Emergencies—An Experimental Feasibility Study
Recent guidelines recommend the umbilical venous catheter (UVC) as the optimal vascular access method during neonatal resuscitation. In emergencies the UVC securement may be challenging and time-consuming. This experimental study was designed to test the feasibility of new concepts for the UVC securement. Umbilical cord remnants were catheterized with peripheral catheters and secured with disposable umbilical clamps. Three different securement te…
PFOE or pFTOE as an Early Marker for Impaired Peripheral Microcirculation in Neonates
The higher pFOE compared to pFTOE suggests a higher potential of pFOE to detect impaired microcirculation, especially when oxygen extraction is elevated
Telesimulation for the Training of Medical Students in Neonatal Resuscitation
Background: Telesimulation may be an alternative to face-to-face simulation-based training. Therefore, we investigated the effect of a single telesimulation training in inexperienced providers. Methods: First-year medical students were recruited for this prospective observational study. Participants received a low-fidelity mannequin and medical equipment for training purposes. The one-hour telesimulation session was delivered by an experienced tr…
Medicine (7 works) · Internal Medicine (5 works) · Anesthesia (4 works) · Neonatal Respiratory Health Research (4 works) · Cardiac Arrest and Resuscitation (3 works) · Cardiology (3 works) · Non-Invasive Vital Sign Monitoring (3 works) · Oxygen (3 works) · Resuscitation (3 works) · Caesarean section (2 works)