Paweł Stefańczyk
Biographic Data
| ID | 7869682 |
|---|---|
| NAME | Paweł Stefańczyk |
| GIVEN NAMES | Paweł |
| FAMILY NAME | Stefańczyk |
| SIGNATURE | STEFAŃCZYK P |
| AFFILIATIONS | John Paul II Hospital |
| ORCID | 0000-0002-4106-3804 |
| VERIFIED | Yes |
| TOTAL WORKS | 6 |
| TOTAL CITATIONS | 0 |
| WORKS AS AUTHOR | 6 |
| WORKS AS EDITOR | 0 |
| FIRST PUBLICATION YEAR | 2021 |
| LATEST PUBLICATION YEAR | 2022 |
| H-INDEX | 0 |
Safety and Effectiveness of Transvenous Lead Extraction in Patients with Infected Cardiac Resynchronization Therapy Devices; Is It More Risky than Extraction of Other Systems
Background: Transvenous lead extraction (TLE) in patients with implantable cardioverter defibrillator (ICD) and cardiac resynchronization therapy (CRT) devices is considered as more risky. The aim of this study was to assess the safety and effectiveness of TLE in patients with infected CRT systems. Methods: Data of 3468 patients undergoing TLE in a single high-volume center in years 2006−2021 were analyzed. The clinical and procedural parameters …
Efficacy and Safety of Transvenous Lead Extraction at the Time of Upgrade from Pacemakers to Cardioverter-Defibrillators and Cardiac Resynchronization Therapy
Upgrading a patient from an existing pacemaker to an ICD/CRT is feasible in 100% of cases, provided that TLE is performed for venous access. Major complications of TLE at the time of device upgrade are rare and, if present do not result in death
Ghost”, a Well-Known but Not Fully Explained Echocardiographic Finding during Transvenous Lead Extraction
The degree of growth and maturation of scar tissue surrounding the lead was the strongest factor leading to the development of both types of ghosts. The presence of either form of ghost did not affect long-term survival even after TLE indicated for infection
The Influence of Lead-Related Venous Obstruction on the Complexity and Outcomes of Transvenous Lead Extraction
LRVSO can be considered as an additional TLE-related risk factor. The effect of LRVSO on major complications including periprocedural mortality and on short-term mortality has not been established. However, LRVSO has been associated with poor long-term survival
Analysis of Risk Factors for Major Complications of 1500 Transvenous Lead Extraction Procedures with Especial Attention to Tricuspid Valve Damage
The risk factors for CVWT and TVD are similar, and the most important ones are related to long lead dwell time and its consequences for the heart (various forms of fibrotic scarring). The occurrence of procedural complications does not affect long-term survival in patients undergoing lead extraction
A Study of Major and Minor Complications of 1500 Transvenous Lead Extraction Procedures Performed with Optimal Safety at Two High-Volume Referral Centers
Background: Transvenous lead extraction (TLE) is the preferred management strategy for complications related to cardiac implantable electronic devices. TLE sometimes can cause serious complications. Methods: Outcomes of TLE procedures using non-powered mechanical sheaths were analyzed in 1500 patients (mean age 68.11 years; 39.86% females) admitted to two high-volume centers. Results: Complete procedural success was achieved in 96.13% of patients…
No prominent works on this page.
The Influence of Lead-Related Venous Obstruction on the Complexity and Outcomes of Transvenous Lead Extraction
LRVSO can be considered as an additional TLE-related risk factor. The effect of LRVSO on major complications including periprocedural mortality and on short-term mortality has not been established. However, LRVSO has been associated with poor long-term survival
Analysis of Risk Factors for Major Complications of 1500 Transvenous Lead Extraction Procedures with Especial Attention to Tricuspid Valve Damage
The risk factors for CVWT and TVD are similar, and the most important ones are related to long lead dwell time and its consequences for the heart (various forms of fibrotic scarring). The occurrence of procedural complications does not affect long-term survival in patients undergoing lead extraction
A Study of Major and Minor Complications of 1500 Transvenous Lead Extraction Procedures Performed with Optimal Safety at Two High-Volume Referral Centers
Background: Transvenous lead extraction (TLE) is the preferred management strategy for complications related to cardiac implantable electronic devices. TLE sometimes can cause serious complications. Methods: Outcomes of TLE procedures using non-powered mechanical sheaths were analyzed in 1500 patients (mean age 68.11 years; 39.86% females) admitted to two high-volume centers. Results: Complete procedural success was achieved in 96.13% of patients…
Safety and Effectiveness of Transvenous Lead Extraction in Patients with Infected Cardiac Resynchronization Therapy Devices; Is It More Risky than Extraction of Other Systems
Background: Transvenous lead extraction (TLE) in patients with implantable cardioverter defibrillator (ICD) and cardiac resynchronization therapy (CRT) devices is considered as more risky. The aim of this study was to assess the safety and effectiveness of TLE in patients with infected CRT systems. Methods: Data of 3468 patients undergoing TLE in a single high-volume center in years 2006−2021 were analyzed. The clinical and procedural parameters …
Efficacy and Safety of Transvenous Lead Extraction at the Time of Upgrade from Pacemakers to Cardioverter-Defibrillators and Cardiac Resynchronization Therapy
Upgrading a patient from an existing pacemaker to an ICD/CRT is feasible in 100% of cases, provided that TLE is performed for venous access. Major complications of TLE at the time of device upgrade are rare and, if present do not result in death
Ghost”, a Well-Known but Not Fully Explained Echocardiographic Finding during Transvenous Lead Extraction
The degree of growth and maturation of scar tissue surrounding the lead was the strongest factor leading to the development of both types of ghosts. The presence of either form of ghost did not affect long-term survival even after TLE indicated for infection
Cardiac Arrhythmias and Treatments (6 works) · Cardiac pacing and defibrillation studies (6 works) · Lead (geology (6 works) · Medicine (6 works) · Cardiology (4 works) · Internal Medicine (4 works) · Cardiac electrophysiology and arrhythmias (3 works) · Ejection fraction (3 works) · Extraction (chemistry (3 works) · Heart failure (3 works)