Pular para o conteúdo principal

ETHNOS_APP

Início • Busca • Periódicos • Lista 0

The Usage of an Air Purifier Device with Hepa 14 Filter during Dental Procedures in Covid-19 Pandemic

A Randomized Clinical Trial

Dados Bibliográficos

ID15499983
AutoresPaolo Capparè (0000-0002-7277-6583, Vita-Salute San Raffaele University, autor correspondente), Raffaele D’Ambrosio (0000-0001-5178-5416, Vita-Salute San Raffaele University), Renato De Cunto (0000-0002-1396-3004, Vita-Salute San Raffaele University), Atanaz Darvizeh (0000-0003-3354-7208, Vita-Salute San Raffaele University), Matteo Nagni (Vita-Salute San Raffaele University), Enrico Gherlone (0000-0002-5193-8467, Vita-Salute San Raffaele University)
Ano2022
Volume19
Fascículo9
Páginas5139-5139
Data de publicação2022-04-23
Open AccessSim
TipoARTICLE
PeriódicoInternational Journal of Environmental Research and Public Health (JOURNAL)
Identificadores do periódicoISSN: 1661-7827 • E-ISSN: 1660-4601
EditoraMultidisciplinary Digital Publishing Institute (PUBLISHER • CH)
DOI10.3390/ijerph19095139
PMID35564533
OpenAlexW4224284493
IdiomaEN
Referências citadas9

The aim of the present study was to evaluate the efficacy of an air purifier device (professional XXl inn-561 innoliving) with HEPA 14 filter in reducing the number of suspended particles generated during dental procedures as a vector of COVID-19 transmission. The survey was conducted on 80 individuals who underwent Oral Surgery with dental Hygiene Procedures, divided into two groups based on the operational risk classification related to dental procedures: a Test Group (with application of filtering device) and a Control Group (without filtering device). All procedures were monitored throughout the clinical controls, utilising professional tools such as molecular particle counters (Lasair III 350 L 9.50 L/min), bacteriological plates (Tryptic Soy Agar), sound meters for LAFp sound pressure level (SPL) and LCpk instantaneous peak level. The rate of suspended particles, microbiological pollution and noise pollution were calculated. SPSS software was used for statistical analysis method. The results showed the higher efficacy of the TEST Group on pollution abatement, 83% more than the Control fgroup. Additionally, the contamination was reduced by 69-80%. Noise pollution was not noticeable compared to the sounds already present in the clinical environment. The addition of PAC equipment to the already existing safety measures was found to be significantly effective in further microbiological risk reduction

Coronavirus disease 2019 (COVID-19 · Filter (signal processing · HEPA · Infection control · Pathology · Computer Science · COVID-19 and healthcare impacts · Dental Research and COVID-19 · Dentistry · Environmental Science · Infection Control and Ventilation · Medicine · Surgery

  • Indoor Air Quality Evaluation Using Mechanical Ventilation and Portable Air Purifiers in an Academic Dentistry Clinic during the Covid-19 Pandemic in Greece

    Open Access•Ιoannis Tzoutzas, Helena C Maltezou et al.•International Journal of…•2021

Altamente citadoNão

Ferramentas

Abrir DOIOpen Access
Ethnos_APP • Projeto Open Source • Licença MIT • Frontend v2.0.0 • Privacidade e Cookies • Documentação da API: api.ethnos.app/docs • Código da API: GitHub • DOI: 10.5281/zenodo.17049435 • Código do Frontend: GitHub • DOI: 10.5281/zenodo.17050053 • cruz.rio.br • Expectantes Misericordiae