AutoresJanet Gaskin (0000-0001-5326-4921, National Research Council Canada, autor correspondente), Liang Grace Zhou (0000-0003-1965-586X, National Research Council Canada), Yunyi Li (0009-0009-8957-6295, National Research Council Canada), Yunyi Ethan Li, Patrique Tardif (National Research Council Canada)
Ano2025
Volume13
Páginas1569494-1569494
Data de publicação2025-04-10
Open AccessSim
TipoARTICLE
PeriódicoFrontiers in Public Health (JOURNAL)
Identificadores do periódicoISSN: 2296-2565 • E-ISSN: 2296-2565
EditoraFrontiers Media SA (PUBLISHER • CH)
DOI10.3389/fpubh.2025.1569494
PMID40337740
OpenAlexW4409302597
IdiomaEN
Referências citadas13

Introduction: Balanced mechanical ventilation with heat (sensible heat only) or energy (sensible and latent heat) recovery has the potential to dilute indoor radon and may be an appropriate first step at reducing moderate indoor radon concentration in a house with mechanical exhaust only. A field study of the effectiveness of heat/energy recovery ventilation systems at reducing moderate indoor radon concentration was conducted in 13 occupied houses and three test houses in Canada. Controlled experiments were also conducted at the test houses to evaluate indoor radon concentration under different depressurization and ventilation scenarios. Methods: In the field study of heat recovery ventilation systems (HRVs) in occupied homes, the indoor radon concentration was measured for different HRV settings within a season to estimate the effectiveness of radon reduction. In the controlled depressurization experiments in the test houses, the change in pressure of the basement relative to the subslab and of the basement, main floor and second floor relative to outdoors was evaluated for a range of mechanical exhaust ventilation scenarios. Results: . The median (25th-75th percentiles) effectiveness of radon reduction was 39% (29-50) for continuous HRV operation at high fan speed in the 12 field study houses where it was connected directly to the forced air furnace heating systems. In the test houses, the sustained operation of mechanical exhaust ventilation devices, however, increased the depressurization and the indoor radon concentration, and the indoor radon concentrations observed at the depressurization of -5 Pa were higher than those observed at -10 and -20 Pa. Conclusion: Balanced mechanical ventilation with heat recovery was shown to be an effective radon control strategy in a field study of occupied houses with a moderate initial indoor radon concentration. Improving the energy efficiency of the existing housing stock is a priority in many countries, and including balanced mechanical ventilation systems may be an effective radon control option when conducting energy retrofits in existing houses

Environmental health · Environmental planning · Geography · Meteorology · Radon · Air Quality and Health Impacts · Computer Science · Earthquake Detection and Analysis · Environmental Science · Medicine · Radioactivity and Radon Measurements · Artificial Intelligence