Pular para o conteúdo principal

ETHNOS_APP

Início • Busca • Periódicos • Lista 0

Variations in US Hospital Performance on Imaging-use Measures

Dados Bibliográficos

ID9101239
AutoresJason S Mathias (Northwestern University), Joe Feingla (0000-0002-3665-8897, Northwestern University), Joe Feinglass, David W Baker (0000-0001-7349-7554, Northwestern University)
Ano2012
Volume50
Fascículo9
Páginas808-814
Data de publicação2012-09-01
Peer ReviewedSim
Open AccessNão
TipoARTICLE
PeriódicoMedical Care (JOURNAL)
Identificadores do periódicoISSN: 0025-7079 • E-ISSN: 1537-1948
EditoraOvid Technologies (Wolters Kluwer Health) (PUBLISHER)
DOI10.1097/mlr.0b013e31825a8c48
PMID22643196
OpenAlexW1963906887
IdiomaEN
Citações recebidas1
Referências citadas19

BACKGROUND: The Hospital Outpatient Quality Reporting Program (HOQR) publicly reports measures of US hospitals' use of 4 imaging studies that may be problematic if overused: magnetic resonance imaging (MRI) for low back, follow-up imaging after screening mammography, and abdominal and thoracic computed tomography (CT) with and without contrast. OBJECTIVES: To characterize performance on these measures, determine whether performance was consistent across measures, and identify hospital characteristics associated with highest-decile imaging use. RESEARCH DESIGN: Cross-sectional analysis. MEASUREMENTS: Correlation across measures was assessed using Spearman rank order tests. We linked 2008 HOQR data to the 2009 American Hospital Association Survey and used multivariable logistic regression to examine associations between hospital characteristics and the likelihood of highest-decile imaging use. RESULTS: Imaging use varied widely. Imaging use was weakly correlated (ρ<0.10) across most measures. Compared with hospitals with moderate imaging volume (25th to 75th percentile), hospitals with low volume (<25th percentile) were more likely to report highest-decile imaging use on all measures [adjusted odds ratios (95% confidence interval) range from 1.38 (1.05-1.80) for CT Abdomen to 4.22 (3.04-5.84) for MRI Back]. Rural hospitals were more likely to report highest-decile use on most measures [MRI: 1.42 (1.21-1.68), CT Abdomen: 1.46 (1.28-1.66), and CT Thorax: 1.32 (1.16-1.51)]. For-profit hospitals were more likely to report highest-decile use on mammography [1.47 (1.10-1.98)] and CT Thorax measures [1.71 (1.28-2.27)]. CONCLUSIONS: Wide variations in imaging use and extraordinarily high use at some hospitals may indicate that imaging overuse occurs at US hospitals. The effectiveness of the HOQR measures to decrease imaging overuse remains to be seen

MEDLINE · Political science · Healthcare cost, quality, practices · Healthcare Policy and Management · Medicine · Radiation Dose and Imaging

  • Institutionalizing Hipaa Compliance

    Open Access•D Anthony, Denise L Anthony et al.•Journal of Health and Social…•2014

  • Is Volume Related to Outcome in Health Care? A Systematic Review and Methodologic Critique of the Literature

    Open Access•Ethan A Halm, Clara Lee et al.•Annals of Internal Medicine•2002

  • Threshold Volumes Associated With Higher Survival in Health Care

    Afschin Gandjour, Angelika Bannenberg et al.•Medical Care•2003

Obras citantes distintas1
Citações por ano0,08
Intervalo de citações2014 - 2014 (1)
Velocidade de citaçãohistorical
Altamente citadoNão
Tipos de citaçãoNeutras: 1
Ethnos_APP • Projeto Open Source • Licença MIT • Frontend v2.0.0 • Privacidade e Cookies • Documentação da API: api.ethnos.app/docs • Código da API: GitHub • DOI: 10.5281/zenodo.17049435 • Código do Frontend: GitHub • DOI: 10.5281/zenodo.17050053 • cruz.rio.br • Expectantes Misericordiae