Métodos alternativos para a detecção de pirogênios em produtos e ambientes sujeitos a Vigilância Sanitária
Avanços e perspectivas no Brasil a partir do reconhecimento internacional do Teste de Ativação de Monócitos
Bibliographic Data
| ID | 13082525 |
|---|---|
| Authors | Cristiane Caldeira da Silva (Fundação Oswaldo Cruz), Carolina Barbara Nogueira de Oliveira (Fundação Oswaldo Cruz), Patrícia dos Santos Carneiro (Instituto Butantan), Eliana Marengo (Instituto Butantan), Eliana Blini Marengo, Katherine A Mattos (0000-0001-5593-5442, Fundação Oswaldo Cruz), Ricardo Sérgio Almeida (0000-0002-1427-936X, Universidade Estadual de Londrina), Ricardo Sérgio Couto de Almeida, Janaína Spoladore (Hospital Universitário Antônio Pedro), Gutemberg Gomes Alves (0000-0003-0016-4809, Hospital Universitário Antônio Pedro), Octávio Augusto França Presgrave (0000-0002-1764-9397, Fundação Oswaldo Cruz), Isabella Fernandes Delgado (0000-0003-0610-5324, Fundação Oswaldo Cruz) |
| Year | 2018 |
| Volume | 6 |
| Issue | 1 |
| Pages | 137-137 |
| Publication date | 2018-02-28 |
| Open Access | Yes |
| Type | ARTICLE |
| Venue | Vigilância Sanitária em Debate (JOURNAL) |
| Journal identifiers | ISSN: 2317-269X |
| Publisher | Oswaldo Cruz Foundation (PUBLISHER • BR) |
| DOI | 10.22239/2317-269x.01082 |
| OpenAlex | W2793861589 |
| Language | PT |
Introduction: The detection of pyrogens is essential for the quality control of injectable products. The Rabbit Pyrogen Test remains widely used, despite the existence of alternative methods such as the Monocyte Activation Test (MAT). Objective: To review the use of alternative methods for pyrogen testing, pointing out advances and perspectives from the recognition of MAT by the European pharmacopoeia and its acceptance for regulatory purposes in Brazil. Method: A search was performed on the PubMed and BVS databases, with further classification, categorization by topic and critical analysis of the results. Results: Twenty-four papers were identified, addressing topics such as applications of MAT, its validation and comparisons with in vivo tests. MAT presented better results when compared to other tests, both in the evaluation of biological products and in the detection of non-endotoxin pyrogens. Limitations to diffusion include difficulties in obtaining whole human blood as a source of monocytes, for which several alternatives have been proposed. Conclusions: MAT is a promising method, with application in safety evaluation of new technologies. Its application in Brazil depends on a national implementation policy, which might include greater integration between BraCVAM, Concea and RENAMA in search for its recognition for regulatory purposes
| Highly cited | No |
|---|