Façade Strategies for Climate Resilience

The Impact of Thermal Mass and Albedo on Urban Microclimates Across Different Climatic Zones

Bibliographic Data

ID13112805
AuthorsNoelia Liliana Alchapar (0000-0003-2682-3163, Centro Científico Tecnológico - Mendoza, corresponding author), Emanuela Giancola (0000-0003-2450-1494, Centro de Investigaciones Energéticas, Medioambientales y Tecnológicas), Gloria Pérez (0000-0001-6653-3393, Instituto de Ciencias de La Construcción Eduardo Torroja), Maira Ayelén Terraza (0009-0007-7107-9886, Centro Científico Tecnológico - Mendoza), Cláudia Cotrim Pezzuto (0000-0002-7609-0263, Pontifícia Universidade Católica de Campinas)
Year2025
Volume9
Issue10
Pages428-428
Publication date2025-10-16
Open AccessYes
TypeARTICLE
VenueUrban Science (JOURNAL)
Journal identifiersISSN: 2413-8851 • E-ISSN: 2413-8851
PublisherMDPI AG (PUBLISHER • IT)
DOI10.3390/urbansci9100428
OpenAlexW4415301315
LanguagePT
Citations received1
References cited33

The intensification of thermal stress in cities due to urbanization and climate change underscores the urgent need to improve outdoor habitability. This study analyses the influence of three opaque façade technologies—traditional, lightweight and external thermal insulation composite systems—combined with two albedo levels (0.30 and 0.80), on summer outdoor conditions in Mendoza (Argentina), Madrid (Spain) and Campinas (Brazil). Using a calibrated microclimatic model with ENVI-met v5.6 software, a digital replica of a 10-storey urban canyon was simulated to generate 18 scenarios, assessing the effect of façade thermal mass and reflectivity on the urban microclimate. The results show that (i) scenarios that mainly affect air temperature (AT) are those that modify the thermal mass of the façade technologies. For example, traditional technology with a low albedo reduce maximum AT by up to 1.2 °C in Campinas, 0.89 °C in Mendoza, and 0.81 °C in Madrid compared to light technology with the same albedo level. (ii) Mean radiant temperature (MRT) increases significantly in scenarios involving lightweight façade by 4.53 °C in Madrid, 4.46 °C in Mendoza, and 3.39 °C in Campinas. Conversely, increasing façade albedo further amplifies MRT due to multiple reflections in urban canyons with increases of 6.50 °C in Campinas, 6.09 °C in Mendoza, and 5.33 °C in Madrid. The impact is more pronounced with traditional façades. (iii) Traditional façades and low-albedo ETIC systems experience the fewest hours of very high thermal stress (UTCI > 38 °C), whereas lightweight façades increase exposure to extreme heat. Overall, air temperature is primarily determined by façade thermal mass, mean radiant temperature by surface reflectivity, and thermal comfort by the combined effect of both. These findings confirm that high reflectivity can be counterproductive in dense urban canyons, emphasizing the importance of climate- and morphology-sensitive façade strategies for urban resilience

Albedo (alchemy · Canyon · Climate change · Mean radiant temperature · Microclimate · Thermal · Thermal comfort · Urban heat island · Building Energy and Comfort Optimization · Urban Green Space and Health · Urban Heat Island Mitigation

  • The cool façade paradox

    Open Access•Natasha Hansen Gapski, Saulo Guths et al.•Sustainable Cities and Society•2026

  • Heat Wave

    Eric Klinenberg•Heat Wave•2015

  • Updated world map of the Köppen-Geiger climate classification

    Open Access•Murray Peel, M C Peel et al.•Hydrology and earth system sciences•2007

  • Numerical study on the effects of aspect ratio and orientation of an urban street canyon on outdoor thermal comfort in hot and dry climate

    Open Access•Fazia Ali-Toudert, Helmut Mayer•Building and Environment•2006

  • The use of reflective materials as a strategy for urban cooling in an arid “Oasis” city

    Open Access•Noelia Liliana Alchapar, Erica Norma Correa Cantaloube et al.•Sustainable Cities and Society•2016

  • Analyzing the Envi-met microclimate model’s performance and assessing cool materials and urban vegetation applications–A review

    Open Access•Στέλλα Τσόκα, S Tsoka et al.•Sustainable Cities and Society•2018

  • Prediction of surface temperature of building surrounding envelopes using holistic microclimate Envi-met model

    Open Access•Aysan Forouzandeh•Sustainable Cities and Society•2021

  • Analyzing urban thermal comfort changes due to modifications in urban material properties in a large-scale new town

    Open Access•Jaekyoung Kim, Samuel Park et al.•Sustainable Cities and Society•2025

  • Simulating the Thermal-Energy Performance of Buildings at the Urban Scale

    Anna Laura Pisello, Veronica Lucia Castaldo et al.•Journal of Urban Technology•2014

Citations per year1
Citation span2026 - 2026 (1)
Highly citedNo

Tools

Open DOIOpen Access
Ethnos_APP • Open Source Project • MIT License • Frontend v2.0.0 • Privacy and Cookies • API Documentation: api.ethnos.app/docs • API Source Code: GitHub • DOI: 10.5281/zenodo.17049435 • Frontend Source Code: GitHub • DOI: 10.5281/zenodo.17050053 • cruz.rio.br • Expectantes Misericordiae