Skip to main content

ETHNOS_APP

Home • Search • Journals • List 0

Le jardin botanique

Une image de la nature

Bibliographic Data

ID15049548
AuthorsJean-Marc Drouin (corresponding author), J DROUIN
Year2000
Volume8
Issue3
Pages81-82
Publication date2000-07-01
Open AccessYes
TypeARTICLE
VenueNatures Sciences Sociétés (JOURNAL)
Journal identifiersISSN: 1240-1307 • E-ISSN: 1765-2979
PublisherElsevier BV (PUBLISHER)
DOI10.1016/s1240-1307(00)80071-0
OpenAlexW1979714540
LanguageEN

Nowadays, the safety of cosmetics is a widespread concern. Amines are common cosmetic additives. Some of them such as amino acids are beneficial. Another kind of amines, however, ε-aminocaproic acid (EACA) is prohibited to add into cosmetics for its adverse reactions. In this study, a simple, rapid, sensitive and eco-friendly one-step ultrasonic-assisted extraction and derivatization (UAE-D) method was developed for determination of EACA and amino acids in cosmetics by coupling with high-performance liquid chromatography (HPLC). By using this sample preparation method, extraction and derivatization of EACA and amino acids were finished in one step in ultrasound field. During this procedure, 4-fluoro-7-nitrobenzofurazan (NBD-F)was applied as derivatization reagent. The extraction conditions including the amount of NBD-F, extraction and derivatization temperature, the ultrasonic vibration time and pH value of the aqueous phase were evaluated. Meanwhile, the extraction mechanism was investigated. Under optimized conditions, the method detection limits were 0.086–0.15 μg/L, and method quantitation limits were 0.29–0.47 μg/L with RSDs less than 3.7% (n = 3). The recoveries of EACA and amino acids obtained from cosmetic samples were in range from 76.9% to 122.3%. Amino acids were found in all selected samples and quantified in range from 1.9 ± 0.9 to 677.2 ± 17.9 μg/kg. And EACA was found and quantified with the contents of 1284.3 ± 22.1 μg/kg in a toner sample. This UAE-D-HPLC method shortened and simplified the sample pretreatment as well as enhanced the sensitivity of analytical method. In our record, only 10 min was needed for the total sample preparation process. And the method detection limits were two orders of magnitude less than literature reports. Furthermore, we reduced the consumption of solvent and minimized the usage of organic solvents, which made our method moving towards green analytical chemistry. In brief, our UAE-D-HPLC method is a simple, rapid, sensitive and eco-friendly analytical method for the determination of EACA and amino acids in cosmetics

Amino acid · Chromatography · Cosmetics · Derivatization · Detection limit · Extraction (chemistry · High-performance liquid chromatography · Reagent · Sample Preparation · Solid phase extraction · Biochemical Analysis and Sensing Techniques · Chemistry · Food Quality and Safety Studies · Tea Polyphenols and Effects · Organic Chemistry

Highly citedNo

Tools

Open DOISci-HubOpen Access
Ethnos_APP • Open Source Project • MIT License • Frontend v2.0.0 • Privacy and Cookies • API Documentation: api.ethnos.app/docs • API Source Code: GitHub • DOI: 10.5281/zenodo.17049435 • Frontend Source Code: GitHub • DOI: 10.5281/zenodo.17050053 • cruz.rio.br • Expectantes Misericordiae