Skip to main content

ETHNOS_APP

Home • Search • Journals • List 0

Hemodynamic Effects of Permanent His Bundle Pacing Compared to Right Ventricular Pacing Assessed by Two-Dimensional Speckle-Tracking Echocardiography

Bibliographic Data

ID15458698
AuthorsJędrzej Michalik (0000-0001-5938-8079, Kashubian Center for Heart and Vascular Diseases, Department of Cardiology and Interventional Angiology, Pomeranian Hospitals, 84-200 Wejherowo, Poland), Alicja Dąbrowska-Kugacka (0000-0002-5546-7818, Gdańsk Medical University), Katarzyna Kosmalska (0000-0001-7132-8116, Pomeranian Medical University), Roman Moroz (Kashubian Center for Heart and Vascular Diseases, Department of Cardiology and Interventional Angiology, Pomeranian Hospitals, 84-200 Wejherowo, Poland), Adrian Kot (Kashubian Center for Heart and Vascular Diseases, Department of Cardiology and Interventional Angiology, Pomeranian Hospitals, 84-200 Wejherowo, Poland), Ewa Lewicka (0000-0002-6286-3886, Gdańsk Medical University), Marek Szołkiewicz (0000-0002-0367-4014, Kashubian Center for Heart and Vascular Diseases, Department of Cardiology and Interventional Angiology, Pomeranian Hospitals, 84-200 Wejherowo, Poland, corresponding author)
Year2021
Volume18
Issue21
Pages11721-11721
Publication date2021-11-08
Open AccessYes
TypeARTICLE
VenueInternational Journal of Environmental Research and Public Health (JOURNAL)
Journal identifiersISSN: 1661-7827 • E-ISSN: 1660-4601
PublisherMultidisciplinary Digital Publishing Institute (PUBLISHER • CH)
DOI10.3390/ijerph182111721
PMID34770235
OpenAlexW3212014666
LanguageEN
Citations received1
References cited28

We compared the effects of right ventricular (RVP; n = 26) and His bundle (HBP; n = 24) pacing in patients with atrioventricular conduction disorders and preserved LVEF. Postoperatively (1D), and after six months (6M), the patients underwent global longitudinal strain (GLS) and peak systolic dispersion (PSD) evaluation with 2D speckle-tracking echocardiography, assessment of left atrial volume index (LAVI) and QRS duration (QRSd), and sensing/pacing parameter testing. The RVP threshold was lower than the HBP threshold at 1D (0.65 ± 0.13 vs. 1.05 ± 0.20 V, p p p p p p p p 2 , p 2 , p < 0.01). These results confirm that HBP does not disrupt ventricular synchrony and provides advantages over RVP

Bundle · Cardiology · Ejection fraction · Heart failure · Hemodynamics · Speckle pattern · Speckle tracking echocardiography · Ventricular pacing · Cardiac Arrhythmias and Treatments · Cardiac pacing and defibrillation studies · Cardiovascular Function and Risk Factors · Computer Science · Materials Science · Medicine · Artificial Intelligence · Internal Medicine

  • Leadless AV Pacemaker in Patient with Complete Heart Block and Bilaterally Implanted Two Deep Brain Stimulators Can Be Safe Therapeutic Option

    Open Access•Jędrzej Michalik, Jonasz Kozielski et al.•International Journal of…•2022

Citations per year0.25
Citation span2022 - 2022 (1)
Highly citedNo

Tools

Open DOIOpen Access
Ethnos_APP • Open Source Project • MIT License • Frontend v2.0.0 • Privacy and Cookies • API Documentation: api.ethnos.app/docs • API Source Code: GitHub • DOI: 10.5281/zenodo.17049435 • Frontend Source Code: GitHub • DOI: 10.5281/zenodo.17050053 • cruz.rio.br • Expectantes Misericordiae