Radiation Dose to the Eye Lens through Radiological Imaging Procedures at the Surgical Workplace during Trauma Surgery

Bibliographic Data

ID15465197
AuthorsChristian Apelmann (BG Klinikum Hamburg, corresponding author), Birgitt Kowald (0000-0002-5403-3479, BG Klinikum Hamburg), Nils Weinrich (BG Klinikum Hamburg, Bergedorfer Str. 10, 21033 Hamburg, Germany), Jens Dischinger (Northern German Seminar for Radiation Protection gGmbH at the Christian-Albrechts-University Kiel, 24098 Kiel, Germany), Albert Nienhaus (0000-0003-1881-7302, University Medical Center Hamburg-Eppendorf), Klaus Seide (BG Klinikum Hamburg), Heiko Martens (B.A.D. Gesundheitsvorsorge und Sicherheitstechnik GmbH, 21033 Hamburg, Germany), Henrik Martens (0000-0002-5589-983X), Christian Jürgens (BG Klinikum Hamburg)
Year2019
Volume16
Issue20
Pages3850-3850
Publication date2019-10-11
Peer ReviewedYes
Open AccessYes
TypeARTICLE
VenueInternational Journal of Environmental Research and Public Health (JOURNAL)
Journal identifiersISSN: 1661-7827 • E-ISSN: 1660-4601
PublisherMultidisciplinary Digital Publishing Institute (PUBLISHER • CH)
DOI10.3390/ijerph16203850
PMID31614696
OpenAlexW2979804113
LanguageEN
References cited33

Background : Due to the drastic reduction of the eye lens dose limit from 150 mSv per year to 20 mSv per year since 2018, the prospective investigation of the estimated dose of the eye lens by radiological imaging procedures at the surgical site during trauma surgery in the daily work process was carried out. This was also necessary because, as experience shows, with changes in surgical techniques, there are also changes in the use of radiological procedures, and thus an up-to-date inventory can provide valuable information for the assessment of occupationally induced radiation exposure of surgical personnel under the current conditions. Methods : The eye lens radiation exposure was measured over three months for five trauma surgeons, four hand surgeons and four surgical assistants with personalized LPS-TLD-TD 07 partial body dosimeters Hp (0.07). A reference dosimeter was deposited at the surgery changing room. The dosimeters were sent to the LPS (Landesanstalt für Personendosimetrie und Strahlenschutzausbildung) measuring institute (National Institute for Personal Dosimetry and Radiation Protection Training, Berlin) for evaluation after 3 months. The duration of the operation, occupation (assistant, surgeon, etc.), type of surgery (procedure, diagnosis), designation of the X-ray unit, total duration of radiation exposure per operation and dose area product per operation were recorded. Results : Both the evaluation of the dosimeters by the trauma surgeons and the evaluation of the dosimeters by the hand surgeons and the surgical assistants revealed no significant radiation exposure of the eye lens in comparison to the respective measured reference dosimeters. Conclusions : Despite the drastic reduction of the eye lens dose limit from 150 mSv per year to 20 mSv per year, the limit for orthopedic, trauma and hand surgery operations is well below the limit in this setting

Dosimeter · Dosimetry · Eye lens · Lens (geology · Medical physics · Nuclear medicine · Optics · Radiation exposure · Radiological weapon · Thermoluminescent dosimeter · Facial Trauma and Fracture Management · Medicine · Radiation Dose and Imaging · Spinal Fractures and Fixation Techniques · Surgery