Skip to main content

ETHNOS_APP

Home • Search • Journals • List 0

Microbial Air Monitoring in Turbulent Airflow Operating Theatres

Is It Possible to Calculate and Hypothesize New Benchmarks for Microbial Air Load

Bibliographic Data

ID15466336
AuthorsMaria Luisa Cristina (0000-0002-7926-7108, Ente Ospedaliero Ospedali Galliera), Anna Maria Spagnolo (0000-0001-6559-3626, Ente Ospedaliero Ospedali Galliera), Gianluca Ottria (Ente Ospedaliero Ospedali Galliera), Elisa Schinca (0009-0008-1999-8786, Ente Ospedaliero Ospedali Galliera), Chiara Dupont (University of Genoa), Alessio Carbone (0009-0008-9907-3299, Ente Ospedaliero Ospedali Galliera), Martino Oliva (Ente Ospedaliero Ospedali Galliera), Marina Sartini (0000-0002-7127-2893, Ente Ospedaliero Ospedali Galliera, corresponding author)
Year2021
Volume18
Issue19
Pages10379-10379
Publication date2021-10-02
Open AccessYes
TypeARTICLE
VenueInternational Journal of Environmental Research and Public Health (JOURNAL)
Journal identifiersISSN: 1661-7827 • E-ISSN: 1660-4601
PublisherMultidisciplinary Digital Publishing Institute (PUBLISHER • CH)
DOI10.3390/ijerph181910379
OpenAlexW3204801395
LanguageEN
References cited1

Multiple studies have demonstrated the presence of microorganisms commonly associated with surgical site infections (SSIs), in the air within the operating theatre (OT). In some countries such Italy, the limit of microbial concentration in the air for OT with turbulent airflows is 35 CFU/m3 for an empty OT and 180 CFU/m3 during activity. This study aims to hypothesize new benchmarks for the airborne microbial load in turbulent airflow operating theatres in operational and at rest conditions using the percentile distribution of data through a 17-year environmental monitoring campaign in various Italian hospitals that implemented a continuous quality improvement policy. The quartile distribution analysis has shown how in operational and at rest conditions, 75% of the values were below 110 CFU/m3 and 18 CFU/m3, respectively, which can be considered a new benchmark for the monitored OTs. During the initial stages of the monitoring campaign, 28.14% of the concentration values in operational conditions and 29.29% of the values in at rest conditions did not conform to the Italian guidelines’ reference values. In contrast, during the last 5 years, all values in both conditions conformed to the reference values and 98.94% of these values were below the new benchmarks. Continuous improvement has allowed contamination to be reduced to levels well below the current reference values

Air contamination · Air monitoring · Air quality index · Airflow · Benchmark (surveying · Biology · Contamination · Geography · Meteorology · Percentile · Quartile · Reference values · Statistics · Waste management · Engineering · Environmental Science · Infection Control and Ventilation · Mathematics · Medical Device Sterilization and Disinfection · Medicine · Surgical site infection prevention · Ecology · Environmental Engineering · Mechanical Engineering

Highly citedNo

Tools

Open DOIOpen Access
Ethnos_APP • Open Source Project • MIT License • Frontend v2.0.0 • Privacy and Cookies • API Documentation: api.ethnos.app/docs • API Source Code: GitHub • DOI: 10.5281/zenodo.17049435 • Frontend Source Code: GitHub • DOI: 10.5281/zenodo.17050053 • cruz.rio.br • Expectantes Misericordiae