Skip to main content

ETHNOS_APP

Home • Search • Journals • List 0

The Study of the Sterilization of the Indoor Air in Hospital/Clinic Rooms by Using the Electron Wind Generator

Bibliographic Data

ID15479757
AuthorsJózef S Pastuszka (Silesian University of Technology), Walter Mucha (0000-0002-7476-0614, Silesian University of Technology), Agnieszka Wlazło (Institute of Occupational Medicine and Environmental Health), Danuta Lis (Institute of Occupational Medicine and Environmental Health), Ewa Marchwińska-Wyrwał (0000-0002-6505-2755, Medical University of Silesia), Anna Mainka (0000-0002-2499-1764, Silesian University of Technology, corresponding author)
Year2019
Volume16
Issue24
Pages4935-4935
Publication date2019-12-05
Open AccessYes
TypeARTICLE
VenueInternational Journal of Environmental Research and Public Health (JOURNAL)
Journal identifiersISSN: 1661-7827 • E-ISSN: 1660-4601
PublisherMultidisciplinary Digital Publishing Institute (PUBLISHER • CH)
DOI10.3390/ijerph16244935
PMID31817514
OpenAlexW2994189384
LanguageEN
Citations received1
References cited20

(1) Background: Since exposure to airborne bacteria and fungi may be especially hazardous in hospitals and outpatient clinics, it is essential to sterilize the air in such rooms. The purpose of this study was to estimate the decrease in the concentration of airborne bacteria and fungi in the selected hospital and clinic rooms due to the work of the electron wind generator (EWG). (2) Methods: EWG is an air movement and air purification device using a sophisticated combination of electrode topology and specially designed high-voltage power supply. (3) Results: The concentration of both bacteria and fungi in the small patient's room dropped to approximately 25% of the initial (background) concentration. In the larger patient's room, the concentration dropped to 50% and 80% of the background concentration for bacteria and fungi, respectively. (4) Conclusions: The obtained data show that the studied sterilization process can be described by the exponential function of time. Moreover, the application of an activated carbon filter into EWG significantly decreases the concentration of ozone in the sterilized room. Sterilization by EWG significantly changes the characteristic of species and genera of airborne bacteria and shifts the main peak of the size distribution of airborne bacteria into the coarser bio-particles

Bacteria · Biology · Sterilization (economics · Air Quality and Health Impacts · Environmental Science · Indoor Air Quality and Microbial Exposure · Infection Control and Ventilation · Medicine · Toxicology

  • Airborne Microorganism Inactivation by a UV-C LED and Ionizer-Based Continuous Sanitation Air (CSA) System in Train Environments

    Open Access•Giulia Baldelli, Mattia Paolo Aliano et al.•International Journal of…•2022

Citations per year0.25
Citation span2022 - 2022 (1)
Highly citedNo
Open DOISci-HubOpen Access
Ethnos_APP • Open Source Project • MIT License • Frontend v2.0.0 • Privacy and Cookies • API Documentation: api.ethnos.app/docs • API Source Code: GitHub • DOI: 10.5281/zenodo.17049435 • Frontend Source Code: GitHub • DOI: 10.5281/zenodo.17050053 • cruz.rio.br • Expectantes Misericordiae