Skip to main content

ETHNOS_APP

Home • Search • Journals • List 0

Effects of Performing Applied Muscle Tension during Recovery after Phlebotomy in Young, First-Time Donors

A Pilot Study

Bibliographic Data

ID15486534
AuthorsCara H Y Cheung (Hong Kong Polytechnic University), May Ling Khaw (University of Tasmania), Wan Leung (0000-0001-6150-0920, Hong Kong Polytechnic University), Shing Yau Tam (0000-0002-5899-1041, Hong Kong Polytechnic University), Chui Yee Chu (Beijing Red Cross Blood Center), Cheuk Kwong Lee (0000-0002-3939-564X, Beijing Red Cross Blood Center), Lee Sw (0000-0001-5257-2076, Hong Kong Polytechnic University, corresponding author)
Year2021
Volume18
Issue19
Pages10541-10541
Publication date2021-10-08
Peer ReviewedYes
Open AccessYes
TypeARTICLE
VenueInternational Journal of Environmental Research and Public Health (JOURNAL)
Journal identifiersISSN: 1661-7827 • E-ISSN: 1660-4601
PublisherMultidisciplinary Digital Publishing Institute (PUBLISHER • CH)
DOI10.3390/ijerph181910541
PMID34639841
OpenAlexW3203726877
LanguageEN
References cited1

Vasovagal reaction (VVR) compromises donor safety and reduces the subsequent return rates. Performing applied muscle tension (AMT) during phlebotomy may reduce the incidence of VVR. However, the effectiveness of performing AMT after phlebotomy to reduce delayed VVR remains unclear. With ethics approval, 12 young, first-time donors (YFTD) were recruited to study the effects on stroke volume (SV), cardiac output (CO) and systemic vascular resistance (SVR) while performing AMT from needle insertion to end of recovery. Measurements from 12 matched control YFTD were used for comparison. Pre-donation anxiety and VVR severity were assessed. Compared to controls, donors who performed AMT had higher SV (Control: 57 mL vs. AMT: 69 mL, p = 0.045), higher CO (Control: 3.7 L·min -1 vs. AMT: 5.2 L·min -1 , p = 0.006) and lower SVR (Control: 1962 dyn·s·cm -5 vs. AMT: 1569 dyn·s·cm -5 , p = 0.032) during mid-phlebotomy. During recovery, the AMT group retained higher SV, higher CO and lower SVR than the control, but not reaching statistical significance. Practicing AMT during recovery resulted in sustained haemodynamic improvements beyond the donation period, despite the reduction in delayed VVR was insignificant compared to the control group. A larger sample size is needed to validate the effectiveness of performing AMT after donation to mitigate delayed VVR

Anesthesia · Donation · Hemodynamics · Incidence (geometry · Phlebotomy · Blood donation and transfusion practices · Blood transfusion and management · Medicine · Organ Donation and Transplantation · Surgery

Citation velocityhistorical
Highly citedNo

Tools

Open DOIOpen Access
Ethnos_APP • Open Source Project • MIT License • Frontend v2.0.0 • Privacy and Cookies • API Documentation: api.ethnos.app/docs • API Source Code: GitHub • DOI: 10.5281/zenodo.17049435 • Frontend Source Code: GitHub • DOI: 10.5281/zenodo.17050053 • cruz.rio.br • Expectantes Misericordiae