Skip to main content

ETHNOS_APP

Home • Search • Journals • List 0

Reducible Nonunited Type II Odontoid Fracture with Atlantoaxial Instability

Outcomes of Two Different Fixation Techniques

Bibliographic Data

ID15488455
AuthorsTorphong Bunmaprasert (0000-0001-7860-2640, Chiang Mai University), Vorapop Trirattanapikul (Chiang Mai University), Nantawit Sugandhavesa (0000-0003-0194-6327, Chiang Mai University), Areerak Phanphaisarn (0000-0001-5553-4868, Chiang Mai University), Wongthawat Liawrungrueang (0000-0002-4491-6569, Chiang Mai University), Phichayut Phinyo (0000-0002-8543-6254, Chiang Mai University, corresponding author)
Year2021
Volume18
Issue15
Pages7990-7990
Publication date2021-07-28
Open AccessYes
TypeARTICLE
VenueInternational Journal of Environmental Research and Public Health (JOURNAL)
Journal identifiersISSN: 1661-7827 • E-ISSN: 1660-4601
PublisherMultidisciplinary Digital Publishing Institute (PUBLISHER • CH)
DOI10.3390/ijerph18157990
PMID34360289
OpenAlexW3185715332
LanguageEN
References cited23

Displaced nonunited type II odontoid fracture can result in atlantoaxial instability, causing delayed cervical myelopathy. Both Magerl's C1-C2 transarticular screw fixation technique and Harms-Goel C1-C2 screw-rod segmental fixation technique are effective techniques to provide stability. This study aimed to demonstrate the results of two surgical fixation techniques for the treatment of reducible nonunited type II odontoid fracture with atlantoaxial instability. Medical records of patients with reducible nonunited type II odontoid fracture hospitalized for spinal fusion between April 2007 and April 2018 were reviewed. For each patient, specific surgical fixation, either Magerl's C1-C2 transarticular screw fixation technique augmented with supplemental wiring or Harms-Goel C1-C2 screw-rod fixation technique, was performed according to our management protocol. We reported the fusion rate, fusion period, and complications for each technique. Of 21 patients, 10 patients were treated with Magerl's C1-C2 transarticular screw fixation technique augmented with supplemental wiring, and 11 were treated with Harms-Goel C1-C2 screw-rod fixation technique. The bony fusion rate was 100% in both groups. The mean time to fusion was 69.7 (95%CI 53.1, 86.3) days in Magerl's C1-C2 transarticular screw fixation technique and 75.2 (95%CI 51.8, 98.6) days in Harms-Goel C1-C2 screw-rod fixation technique. No severe complications were observed in either group. Displaced reducible, nonunited type II odontoid fracture with cervical myelopathy should be treated by surgery. Both fixation techniques promote bony fusion and provide substantial construct stability

Atlantoaxial instability · Bony fusion · Cervical spine · Fixation (population genetics · Myelopathy · Odontoid process · Population · Radiography · Spinal cord · Hip and Femur Fractures · Medicine · Pelvic and Acetabular Injuries · Spinal Fractures and Fixation Techniques · Surgery

Highly citedNo

Tools

Open DOIOpen Access
Ethnos_APP • Open Source Project • MIT License • Frontend v2.0.0 • Privacy and Cookies • API Documentation: api.ethnos.app/docs • API Source Code: GitHub • DOI: 10.5281/zenodo.17049435 • Frontend Source Code: GitHub • DOI: 10.5281/zenodo.17050053 • cruz.rio.br • Expectantes Misericordiae