Skip to main content

ETHNOS_APP

Home • Search • Journals • List 0

Research on Best Solution for Improving Indoor Air Quality and Reducing Energy Consumption in a High-Risk Radon Dwelling from Romania

Bibliographic Data

ID15493721
AuthorsIon-Costinel Mareș (0000-0002-3606-567X, Technical University of Civil Engineering of Bucharest, corresponding author), Tiberiu Cătălina (0000-0002-9954-0781, Technical University of Civil Engineering of Bucharest, corresponding author), Marian-Andrei Istrate (Technical University of Civil Engineering of Bucharest), Alexandra Cucoș (0000-0001-6466-121X, Babeș-Bolyai University), Tiberius Dicu (0000-0001-5995-1327, Babeș-Bolyai University), Bety-Denissa Burghele (0000-0003-2711-8271, Babeș-Bolyai University), Kinga Hening (Babeș-Bolyai University), Lelia Letiția Popescu (0000-0001-9474-0939, Technical University of Civil Engineering of Bucharest), Razvan Ştefan Popescu (0000-0003-0297-9497, Technical University of Civil Engineering of Bucharest)
Year2021
Volume18
Issue23
Pages12482-12482
Publication date2021-11-26
Open AccessYes
TypeARTICLE
VenueInternational Journal of Environmental Research and Public Health (JOURNAL)
Journal identifiersISSN: 1661-7827 • E-ISSN: 1660-4601
PublisherMultidisciplinary Digital Publishing Institute (PUBLISHER • CH)
DOI10.3390/ijerph182312482
PMID34886208
OpenAlexW3215398160
LanguageEN
References cited2

The purpose of this article is the assessment of energy efficiency and indoor air quality for a single-family house located in Cluj-Napoca County, Romania. The studied house is meant to be an energy-efficient building with thermal insulation, low U-value windows, and a high efficiency boiler. Increasing the energy efficiency of the house leads to lower indoor air quality, due to lack of natural ventilation. As the experimental campaign regarding indoor air quality revealed, there is a need to find a balance between energy consumption and the quality of the indoor air. To achieve superior indoor air quality, the proposed mitigation systems (decentralized mechanical ventilation with heat recovery combined with a minimally invasive active sub-slab depressurization) have been installed to reduce the high radon level in the dwelling, achieving an energy reduction loss of up to 86%, compared to the traditional natural ventilation of the house. The sub-slab depressurization system was installed in the room with the highest radon level, while the local ventilation system with heat recovery has been installed in the exterior walls of the house. The results have shown significant improvement in the level of radon decreasing the average concentration from 425 to 70 Bq/m 3 , respectively the carbon dioxide average of the measurements being around 760 ppm. The thermal comfort improves significantly also, by stabilizing the indoor temperature at 21 °C, without any important fluctuations. The installation of this system has led to higher indoor air quality, with low energy costs and significant energy savings compared to conventional ventilation (by opening windows)

Air quality index · Cabin pressurization · Efficient energy use · Energy consumption · Energy recovery ventilation · Heat exchanger · Heat recovery ventilation · Indoor air quality · Meteorology · Natural Ventilation · Radon · Slab · Structural engineering · Thermal comfort · Ventilation (architecture · Waste management · Building Energy and Comfort Optimization · Engineering · Environmental Science · Noise Effects and Management · Radioactivity and Radon Measurements · Environmental Engineering · Mechanical Engineering