Ultrasonic Assessment of Optic Nerve Sheath Diameter in Patients at Risk of Sepsis-Associated Brain Dysfunction
A Preliminary Report
Bibliographic Data
| ID | 15511717 |
|---|---|
| Authors | Piotr F Czempik (0000-0003-4347-5631, Medical University of Silesia, corresponding author), Jakub Gąsiorek (0000-0002-4129-3773, Medical University of Silesia), Aleksandra BAK (0000-0002-5340-7790, Medical University of Silesia), Łukasz J Krzych (0000-0002-5252-8398, Medical University of Silesia) |
| Year | 2020 |
| Volume | 17 |
| Issue | 10 |
| Pages | 3656-3656 |
| Publication date | 2020-05-22 |
| Open Access | Yes |
| Type | ARTICLE |
| Venue | International Journal of Environmental Research and Public Health (JOURNAL) |
| Journal identifiers | ISSN: 1661-7827 • E-ISSN: 1660-4601 |
| Publisher | Multidisciplinary Digital Publishing Institute (PUBLISHER • CH) |
| DOI | 10.3390/ijerph17103656 |
| PMID | 32456003 |
| OpenAlex | W3027377187 |
| Language | EN |
| Citations received | 1 |
| References cited | 27 |
Sepsis-associated brain dysfunction (SABD) with increased intracranial pressure (ICP) is a complex pathology that can lead to unfavorable outcome. Ultrasonographic measurement of optic nerve sheath diameter (ONSD) is used for non-invasive assessment of ICP. We aimed to assess the role of ONSD as a SABD screening tool. This prospective preliminary study covered 10 septic shock patients (5 men; aged 65, IQR 50-78 years). ONSD was measured bilaterally from day 1 to 10 ( n = 1), until discharge ( n = 3) or death ( n = 6). The upper limit for ONSD was set at 5.7 mm. Sequential organ failure assessment score was calculated on a daily basis as a surrogate formulti-organ failure due to sepsis in the study population. On day 1, the medians of right and left ONSD were 5.56 (IQR 5.35-6.30) mm and 5.68 (IQR 5.50-6.10) mm, respectively, and four subjects had bilaterally elevated ONSD. Forty-nine out of 80 total measurements performed (61%) exceeded 5.7 mm during the study period. We found no correlations between ONSD and sequential organ failure assessment (SOFA) during the study period (right: R = -0.13-0.63; left R = -0.24-0.63). ONSD measurement should be applied for screening of SABD cautiously. Further research is needed to investigate the exact role of this non-invasive method in the assessment of brain dysfunction in these patients
Intracranial pressure · Population · Sepsis · Septic shock · Traumatic brain injury · Hemodynamic Monitoring and Therapy · Medicine · Sepsis Diagnosis and Treatment · Traumatic Brain Injury and Neurovascular Disturbances · Surgery
| Citations per year | 0.17 |
|---|---|
| Citation span | 2020 - 2020 (1) |
| Highly cited | No |