Evaluation of Legionella Air Contamination in Healthcare Facilities by Different Sampling Methods
An Italian Multicenter Study
Bibliographic Data
Healthcare facilities (HF) represent an at-risk environment for legionellosis transmission occurring after inhalation of contaminated aerosols. In general, the control of water is preferred to that of air because, to date, there are no standardized sampling protocols. Legionella air contamination was investigated in the bathrooms of 11 HF by active sampling (Surface Air System and Coriolis ® μ) and passive sampling using settling plates. During the 8-hour sampling, hot tap water was sampled three times. All air samples were evaluated using culture-based methods, whereas liquid samples collected using the Coriolis ® μ were also analyzed by real-time PCR. Legionella presence in the air and water was then compared by sequence-based typing (SBT) methods. Air contamination was found in four HF (36.4%) by at least one of the culturable methods. The culturable investigation by Coriolis ® μ did not yield Legionella in any enrolled HF. However, molecular investigation using Coriolis ® μ resulted in eight HF testing positive for Legionella in the air. Comparison of Legionella air and water contamination indicated that Legionella water concentration could be predictive of its presence in the air. Furthermore, a molecular study of 12 L. pneumophila strains confirmed a match between the Legionella strains from air and water samples by SBT for three out of four HF that tested positive for Legionella by at least one of the culturable methods. Overall, our study shows that Legionella air detection cannot replace water sampling because the absence of microorganisms from the air does not necessarily represent their absence from water; nevertheless, air sampling may provide useful information for risk assessment. The liquid impingement technique appears to have the greatest capacity for collecting airborne Legionella if combined with molecular investigations
Bacteria · Biology · Contamination · Filter (signal processing · Legionella · Legionella pneumophila · Sampling (signal processing · Tap water · Veterinary medicine · Bacterial biofilms and quorum sensing · Chemistry · Dental Research and COVID-19 · Environmental Science · Legionella and Acanthamoeba research · Medicine · Ecology · Environmental Chemistry · Environmental Engineering · Microbiology
A comprehensive review of microbial contamination in the indoor environment
A review of Legionella transmission risk in built environments
Environmental Monitoring of Legionella in Hospitals in the Campania Region
Risk Influence of Some Environmental and Behavioral Factors on Air Contamination in the Operating Room
No-Touch Automated Disinfection System Based on Hydrogen Peroxide and Ethyl Alcohol Aerosols for Use in Healthcare Environments
Evaluation of Air Contamination in Orthopaedic Operating Theatres in Hospitals in Southern Italy
Environmental Surveillance of Legionellosis within an Italian University Hospital—Results of 15 Years of Analysis
Legionella Detection in Water Networks as per ISO 11731
Chemical Pollution in Healing Spaces
Evaluation of Microbiological and Free-Living Protozoa Contamination in Dental Unit Waterlines