Skip to main content

ETHNOS_APP

Home • Search • Journals • List 0

The ‘thirsty’ water-electricity nexus

Field data on the scale and seasonality of thermoelectric power generation’s water intensity in China

Bibliographic Data

ID15546973
AuthorsDaqian Jiang (0000-0003-1661-4165, University of Minnesota, corresponding author), Anu Ramaswami (0000-0002-0476-2315, University of Minnesota), Anuradha Ramaswami
Year2015
Volume10
Issue2
Pages024015-024015
Publication date2015-02-01
Peer ReviewedYes
Open AccessYes
TypeARTICLE
VenueEnvironmental Research Letters (JOURNAL)
Journal identifiersISSN: 1748-9326 • E-ISSN: 1748-9326
PublisherIOP Publishing (PUBLISHER • GB)
DOI10.1088/1748-9326/10/2/024015
OpenAlexW2025910960
LanguageEN
Citations received2
References cited16

There is a lack of field data on the water withdrawal and consumption intensity of thermoelectric power plants in China. With China’s ambitious electricity capacity expansion and ever-growing water deficit, the overlooked water dimension of thermoelectric power generation could soon have significant water sustainability implications, and field data on water intensity of thermoelectric power plants will be essential to further our understanding of China’s water-electricity nexus. To address this knowledge gap, this paper presents field data on the water withdrawal intensity and water balance of 19 coal-fired power plants in Shandong, China, categorized by different generator capacities ( 600 MW) and boiler technologies (subcritical, supercritical and ultra supercritical). This paper suggests that the annual average water withdrawal intensity of coal-fired power plants in Shandong (1.50–3.75 L kWh ^−1 ) is within the range of values reported for other countries, and that the distinction between water withdrawal and water consumption effectively vanishes since very little water is returned from withdrawal. This paper also suggests that there is quite significant seasonality in power plants’ water intensity whereby the water intensity in July can be approximately 15–28% higher than the annual average. The seasonality is on a similar scale across all generator capacities, except for a small co-generation plant (<100 MW), which had substantially lower water intensity in January when a heat exchanger was used to provide heating

Electrical engineering · Electricity · Electricity generation · Intensity (physics · Nexus (standard · Power (physics · Water use · Water-energy nexus · Engineering · Environmental Impact and Sustainability · Environmental Science · Water resources management and optimization · Water-Energy-Food Nexus Studies · Ecology · Environmental Engineering

  • Unreflective use of old data sources produced echo chambers in the water–electricity nexus

    Open Access•Santiago Vaca, P W Gerbens-Leenes et al.•Nature Sustainability•2021

  • A regional assessment of the water embedded in the US electricity system

    Open Access•Rebecca Peer, Emily Grubert et al.•Environmental Research Letters•2019

  • China's environment in a globalizing world

    Open Access•Jianguo Liu, Jared M Diamond et al.•Nature•2005

  • The Water Withdrawal Footprint of Energy Supply to Cities

    Open Access•Elliot Cohen, Anu Ramaswami•Journal of Industrial Ecology•2014

  • Dynamic modelling of water demand, water availability and adaptation strategies for power plants to global change

    Open Access•Hagen Koch, Stefan Vögele•Ecological Economics•2009

  • Electricity generation and cooling water use

    Open Access•Edward Byers, John W Hall et al.•Global Environmental Change•2014

Unique citing works2
Citations per year0.29
Citation span2019 - 2021 (3)
Citation velocityhistorical
Highly citedNo
Citation typesNeutral: 2

Tools

Open DOISci-HubOpen Access
Ethnos_APP • Open Source Project • MIT License • Frontend v2.0.0 • Privacy and Cookies • API Documentation: api.ethnos.app/docs • API Source Code: GitHub • DOI: 10.5281/zenodo.17049435 • Frontend Source Code: GitHub • DOI: 10.5281/zenodo.17050053 • cruz.rio.br • Expectantes Misericordiae