Weight Is More Accurate than Gestational Age When Estimating the Optimal Endotracheal Tube Depth in Neonates
Bibliographic Data
| ID | 15712400 |
|---|---|
| Authors | Hsien-Kuan Liu (0000-0003-0176-1381, I-Shou University), Yung‐Ning Yang (0000-0002-8533-1209, E-Da Hospital), Shu‐Leei Tey (I-Shou University), Shu-Leei Tey (Department of Pediatrics, E-DA Hospital, Kaohsiung 82445, Taiwan), Pei-Ling Wu (0000-0003-3102-6572, Department of Pediatrics, E-DA Hospital, Kaohsiung 82445, Taiwan), Pei‐Ling Wu (0000-0001-8021-5682, I-Shou University), San‐Nan Yang (0000-0003-1276-8546, I-Shou University), San-Nan Yang (Department of Pediatrics, E-DA Hospital, Kaohsiung 82445, Taiwan), Chien-Yi Wu (0000-0003-0585-0293, I-Shou University, corresponding author) |
| Year | 2021 |
| Volume | 8 |
| Issue | 5 |
| Pages | 324-324 |
| Publication date | 2021-04-22 |
| Open Access | Yes |
| Type | ARTICLE |
| Venue | Children (JOURNAL) |
| Journal identifiers | ISSN: 2227-9067 • E-ISSN: 2227-9067 |
| Publisher | Multidisciplinary Digital Publishing Institute (PUBLISHER • CH) |
| DOI | 10.3390/children8050324 |
| PMID | 33922253 |
| OpenAlex | W3157150507 |
| Language | EN |
| References cited | 19 |
Determining the optimal endotracheal tube (ETT) depth in neonates remains challenging for neonatologists. The guideline for optimal ETT depth is based on the patients' weight or gestational age. However, there is a discrepancy in the suggested ETT depth between these two parameters. The aim of this retrospective study was to compare the recommended weight-based and age-based formulas for optimal ETT depth and obtain the optimal reference before intubation. Participants were assigned to group 1 if the recommended ETT insertion depth based on weight was concordant with the recommended depth based on gestational age, and to group 2 if the weight and age-based depth recommendations were discordant. After exclusion, 180 patients were included in the analysis. Results indicated that the predicted ETT depth suggested by age required more adjustment than by weight ( p p p < 0.001). These results imply that when there is a discrepancy in ETT depth between the weight-based and age-based recommendation, the weight-based one will be more accurate than the age-based one
Anesthesia · Biology · Endotracheal tube · Gestational age · Intubation · Obstetrics · Pregnancy · Tube (container · Airway Management and Intubation Techniques · Emergency and Acute Care Studies · Materials Science · Medicine · Neonatal Respiratory Health Research
| Highly cited | No |
|---|