Efficacy of Infrared Vein Visualization versus Standard Technique for Peripheral Venous Cannulation in Infant and Toddler Populations

A Randomized Study

Bibliographic Data

ID15717033
AuthorsGraham Fehr (Children's Hospital of The King's Daughters), Marisa Rigali (0000-0001-7064-9874, Virginia Commonwealth University), Gregory Weller (Penn State Milton S. Hershey Medical Center), Shannon M Grap (0000-0002-8834-4101, Penn State Milton S. Hershey Medical Center), Melissa Coleman (0000-0003-0950-4638, Penn State Milton S. Hershey Medical Center), Uma Parekh (0000-0001-8420-5916, Penn State Milton S. Hershey Medical Center), Vernon M Chinchilli (0000-0001-6488-7809, Pennsylvania State University), Priti G Dalal (0000-0002-6809-810X, Penn State Milton S. Hershey Medical Center, corresponding author)
Year2023
Volume10
Issue10
Pages1652-1652
Publication date2023-10-05
Open AccessYes
TypeARTICLE
VenueChildren (JOURNAL)
Journal identifiersISSN: 2227-9067 • E-ISSN: 2227-9067
PublisherMultidisciplinary Digital Publishing Institute (PUBLISHER • CH)
DOI10.3390/children10101652
PMID37892315
OpenAlexW4387369959
LanguageEN
References cited19

Establishing intravenous (IV) access in younger patient populations via the traditional cannulation technique for procedures requiring anesthesia is often challenging. Infrared (IR) vein visualization is a modality that aids venous cannulation; however, few reports of this technique exist in the infant and toddler population. The primary aim of this study was to compare the efficacy of IR vein visualization to the standard cannulation technique for obtaining peripheral IV access in infant and toddler populations. Following Institutional Review Board (IRB) approval and written informed consent, children were randomly assigned to either a standard cannulation technique group or an IR vein visualization device group for venous cannulation. The primary outcome variable was the success rate of IV cannulation, and the secondary variables were the total number of attempts and the time to successful cannulation. No difference was noted between either group for first-attempt success rate (standard versus IR: 61.25% vs. 54.4%; p = 0.4) or time to establish IV cannulation (standard versus IR: median [interquartile range], 40 s [24-120] vs. 53 s [26-106]; p = 0.55). The anesthesiologist's grading of the anticipated difficulty of IV cannulation was a significant predictor of cannulation success ( p = 0.0016). Our study demonstrated no significant benefit in utilizing the IR vein visualization device in terms of the overall success rate, number of attempts, and time to establish successful IV cannulation when compared to the standard technique. However, in difficult IV access situations, this device proved to be a valuable rescue adjunct

Anesthesia · Interquartile range · Population · Randomized controlled trial · Toddler · Vein · Airway Management and Intubation Techniques · Central Venous Catheters and Hemodialysis · Medicine · Psychology · Vascular anomalies and interventions · Surgery

Highly citedNo