Skip to main content

ETHNOS_APP

Home • Search • Journals • List 0

Human Milk Feeding for Septic Newborn Infants Might Minimize Their Exposure to Ventilation Therapy

Bibliographic Data

ID15718071
AuthorsElisenda Moliner-Calderón (0000-0001-5631-2888, Hospital de Sant Pau), Sergio Verd (0000-0002-2612-0794, Health Research Institute of the Balearic Islands, corresponding author), Alfonso Leiva (0000-0001-5306-8533), Jaume Ponce‐Taylor (0000-0002-4146-2135), Gemma Ginovart (0000-0001-8072-1681, Hospital Universitari Germans Trias i Pujol), Pia Moll-McCarthy (Fundación Hospital Manacor), Catian Gelabert (Hospital Universitario Son Espases), J Figueras Aloy (0000-0003-1261-8193, Hospital Clínic de Barcelona)
Year2022
Volume9
Issue10
Pages1450-1450
Publication date2022-09-22
Open AccessYes
TypeARTICLE
VenueChildren (JOURNAL)
Journal identifiersISSN: 2227-9067 • E-ISSN: 2227-9067
PublisherMultidisciplinary Digital Publishing Institute (PUBLISHER • CH)
DOI10.3390/children9101450
PMID36291386
OpenAlexW4296993024
LanguageEN

Background. It has been well established that human milk feeding contributes to limiting lung diseases in vulnerable neonates. The primary aim of this study was to compare the need for mechanical ventilation between human milk-fed neonates with sepsis and formula-fed neonates with sepsis. Methods. All late preterm and full-term infants from a single center with sepsis findings from 2002 to 2017 were identified. Data on infant feeding during hospital admission were also recorded. Multivariate logistic regression analyses were performed to assess the impact of feeding type on ventilation support and main neonatal morbidities. Results. The total number of participants was 322 (human milk group = 260; exclusive formula group = 62). In the bivariate analysis, 72% of human milk-fed neonates did not require oxygen therapy or respiratory support versus 55% of their formula-fed counterparts (p < 0.0001). Accordingly, invasive mechanical ventilation was required in 9.2% of any human milk-fed infants versus 32% of their exclusively formula-fed counterparts (p = 0.0085). These results held true in multivariate analysis; indeed, any human milk-fed neonates were more likely to require less respiratory support (OR = 0.44; 95% CI:0.22, 0.89) than those who were exclusively formula-fed. Conclusion. Human milk feeding may minimize exposure to mechanical ventilation

Anesthesia · Logistic regression · Mechanical ventilation · Multivariate analysis · Oxygen therapy · Respiratory system · Sepsis · Ventilation (architecture · Infant Development and Preterm Care · Infant Nutrition and Health · Medicine · Neonatal Respiratory Health Research · Internal Medicine · Pediatrics

Highly citedNo

Tools

Open DOIOpen Access
Ethnos_APP • Open Source Project • MIT License • Frontend v2.0.0 • Privacy and Cookies • API Documentation: api.ethnos.app/docs • API Source Code: GitHub • DOI: 10.5281/zenodo.17049435 • Frontend Source Code: GitHub • DOI: 10.5281/zenodo.17050053 • cruz.rio.br • Expectantes Misericordiae