Skip to main content

ETHNOS_APP

Home • Search • Journals • List 0

Safety and Efficacy of Using Advanced Hybrid Closed Loop Off-Label in an Infant Diagnosed with Permanent Neonatal Diabetes Mellitus

A Case Report and a Look to the Future

Bibliographic Data

ID15718362
AuthorsFederico Pezzotta (0009-0009-5022-2027, Istituto Giannina Gaslini), Nicola Sarale (Istituto Giannina Gaslini), Giordano Spacco (0009-0001-9889-5409, Istituto Giannina Gaslini), Giacomo Tantari (0009-0000-4881-5928, Istituto Giannina Gaslini), Enrica Bertelli (Azienda Ospedaliera Nazionale SS. Antonio e Biagio e Cesare Arrigo), Giulia Bracciolini (Azienda Ospedaliera Nazionale SS. Antonio e Biagio e Cesare Arrigo), Andrea Secco (Azienda Ospedaliera Nazionale SS. Antonio e Biagio e Cesare Arrigo), Giuseppe d’Annunzio (0000-0002-1856-2277, Istituto Giannina Gaslini), Mohamad Maghnie (0000-0002-7183-5238, Istituto Giannina Gaslini), Nicola Minuto (0000-0002-5280-6319, Istituto Giannina Gaslini, corresponding author), Marta Bassi (0000-0003-0886-3989, Istituto Giannina Gaslini)
Year2024
Volume11
Issue10
Pages1225-1225
Publication date2024-10-09
Open AccessYes
TypeARTICLE
VenueChildren (JOURNAL)
Journal identifiersISSN: 2227-9067 • E-ISSN: 2227-9067
PublisherMultidisciplinary Digital Publishing Institute (PUBLISHER • CH)
DOI10.3390/children11101225
PMID39457190
OpenAlexW4403250102
LanguageEN
Citations received1

The case report shows the safety and efficacy of insulin treatment with Advanced Hybrid Closed Loop (AHCL) system in a young patient affected by permanent neonatal diabetes mellitus (PNDM) due to chromosome 8 deletion syndrome involving the GATA4 gene. In the first days of life, he presented hyperglycaemia and started an intravenous insulin infusion therapy, replaced by a continuous subcutaneous insulin infusion (CSII) with Medtronic Minimed 780G ® insulin pump (Medtronic, Northridge, CA, USA). At the age of 2 years, the off-label activation of SmartGuard ® automated insulin delivery mode led to a great improvement in glycaemic control, reaching all recommended targets. At the 1-month follow-up visit, Time in Range (TIR) increased from 66% to 79%, with a Time in Tight Range (TTIR) of 55% and a reduction of 11% in time in hyperglycaemia and of 2% in time in hypoglycaemia. During the entire follow-up, no episodes of ketoacidosis or severe hypoglycaemia were observed and the patient maintained the glycaemic recommended targets reached at 1 month. Maintaining optimal glycaemic control and reducing hyperglycaemia are essential for brain growth and neurocognitive development in young patients. AHCL use should be considered to ensure good glycaemic control in patients affected by neonatal diabetes

Closed loop · Control engineering · Diabetes mellitus · Intensive care medicine · Loop (graph theory · Diabetes Management and Research · Engineering · Hyperglycemia and glycemic control in critically ill and hospitalized patients · Medicine · Pancreatic function and diabetes · Endocrinology · Pediatrics

  • Diagnosis and Treatment of Neonatal Diabetes Caused by ATP-Channel Mutations

    Open Access•Michela Trada, Chiara Novara et al.•Children•2025

Citations per year1
Citation span2025 - 2025 (1)
Highly citedNo

Tools