AuthorsG Ganesan Subramanian (0000-0003-1447-7953, Open International University for Alternative Medicines), T Suresh Padmanabhan (0000-0003-3536-4640, Open International University for Alternative Medicines), I A Chidambaram (Annamalai University), B Paramasivam (0000-0003-2435-2767, Annamalai University)
Year2021
Volume24
Issue2
Pages84-94
Publication date2021-06-30
Open AccessNo
TypeARTICLE
VenueNew Materialisms (JOURNAL)
Journal identifiersISSN: 1480-2422 • E-ISSN: 2292-1168
PublisherJournal of New Materials for Electrochemical Systems (PUBLISHER)
DOI10.14447/jnmes.v24i2.a05
OpenAlexW4205598071
LanguageEN

This paper is focused on design and application of Pseudo-Derivative Feedback (PDF) controller for Automatic Generation Control (AGC) of a two-area thermal reheat interconnected power system treated in deregulated condition. The proposed controller gains are tuned simultaneously using Flower Pollination Algorithm (FPA) in order to achieve the optimal transient response of the test system. The control performance of the PDF controller is compared with Proportional Integral (PI) and Proportional Integral Derivative (PID) controllers. Further to improve the AGC performance, Hydrogen Energy Storage (HES) are included in its control area. The execution of HES unit captures the underlying fall in frequency as well as the tie line control power deviations after a sudden load unsettling influence. The simulation results demonstrate that the proposed PDF controller enhance the dynamic response of the deregulated power system as compared with PI and PID contrtoller. The frequency oscillation and tie-line power deviations in the control zones are reduced and the settling time is additionally enhanced when HES unit takes an interest in the frequency regulation along with the traditional generators. Additionally, the Power System Restoration Indices (PSRI) is figured in view of system dynamic performances and the remedial measures to be taken can be decreed. These PSRI shows that the ancillary service requirement to enhances the effectiveness of physical task of the power system with the expanded transmission limit in the system. The presence of an Hydrogen Energy Storage (HES) water electrolyser coupled to a fuel cell improves significantly the control and operation of an energy system and provides good margin of stability of the grid system compared to that a system without HES unit

Automatic frequency control · Automatic Generation Control · Control engineering · Electric power system · Frequency deviation · Physics · PID controller · Settling time · Step response · Telecommunications · Temperature control · Tie line · Computer Science · Engineering · Frequency Control in Power Systems · Microgrid Control and Optimization · Physics of Superconductivity and Magnetism

Highly citedNo

Tools

Open DOIOpen Access
Ethnos_APP • Open Source Project • MIT License • Frontend v2.0.0 • Privacy and Cookies • API Documentation: api.ethnos.app/docs • API Source Code: GitHub • DOI: 10.5281/zenodo.17049435 • Frontend Source Code: GitHub • DOI: 10.5281/zenodo.17050053 • cruz.rio.br • Expectantes Misericordiae