Skip to main content

ETHNOS_APP

Home • Search • Journals • List 0

Assessing the performance of emerging and existing continuous monitoring solutions under a single-blind controlled testing protocol

Bibliographic Data

ID19568262
AuthorsFancy Cheptonui (0009-0003-0001-8649, Colorado State University), Ethan Emerson (0000-0003-0350-3810, Colorado State University), Chiemezie Ilonze (0000-0003-4231-3278, Colorado State University), Rachel Day (0009-0001-9331-1603, Colorado State University), Ezra Levin, Ezra J T Levin (0000-0001-7390-4877, Colorado State University), Daniel Fleischmann, Daniel F Fleischmann (0000-0002-5493-0620, Colorado State University), Ryan Brouwer (Colorado State University), Daniel Zimmerle (0000-0003-2832-048X, Colorado State University)
Year2025
Volume13
Issue1
Publication date2025-09-29
Peer ReviewedYes
Open AccessYes
TypeARTICLE
VenueElementa Science of the Anthropocene (JOURNAL)
Journal identifiersISSN: 2325-1026 • E-ISSN: 2325-1026
PublisherUniversity of California Press (PUBLISHER • US)
DOI10.1525/elementa.2025.00020
OpenAlexW4414658601
LanguageEN
References cited16

Continuous monitoring (CM) solutions can facilitate faster detection and repair of emissions compared to traditional survey methods. This study tested 13 CM solutions over 12 weeks using single-blind controlled testing. Controlled release rates ranged from 0.08 to 6.75 kg CH4 h−1 and lasted 18 min to 8 h. Six solutions demonstrated 90% method detection limits (DL90s) ranging from 0.5 [0.3, 0.6] kg CH4 h−1 to 6.7 [5.9, 8.0] kg CH4 h−1. Of the 6 solutions, 5 had low False Positive (FP) rates (7.8%–18.9%), and 4 had low False Negative (FN) rates (8.0%–34.1%). Similar to Ilonze et al., the results show that the tested solutions balance method sensitivity with low FP and FN rates. All scanning/imaging solutions achieved high localization precision and accuracy (≥40%) at the equipment unit level. Single quantification estimates exhibited high relative quantification errors, ranging from 33 [0.9, 66]%, 95% confidence interval (CI) to 1326 [1003, 1648]%, 95% CI for small emissions (between 0.1 and 1 kg CH4 h−1) and from 3 [−20, 26]%, 95% CI to 3578 [−2832, 9988]%, 95% CI for large emissions (>1 kg CH4 h−1). The mean detection time for all solutions ranged from 5 h to 5 days. Relative to previous studies, errors in quantification estimates decreased, as did FN and FP rates, with improved DL90s for 2 of the 4 retested solutions. However, the mean detection times increased for 2 solutions, remained constant for one solution, and decreased for 1 of the 4 retested solutions. These findings highlight that continuous, rigorous testing enhances solution performance, with notable improvements observed across multiple testing programs using the same test protocol

Confidence interval · Continuous monitoring · Limits of agreement · Ranging · Atmospheric and Environmental Gas Dynamics · Scientific Computing and Data Management · Spectroscopy and Laser Applications

  • Climate Change 2021 – The Physical Science Basis

    Open Access•Intergovernmental Panel On Climate Change, Intergovernmental Panel…•Climate Change 2021 - the…•2023

  • Methane Leaks from North American Natural Gas Systems

    Open Access•Adam R Brandt, Garvin Heath et al.•Science•2014

  • Evaluation of next generation emission measurement technologies under repeatable test protocols

    Open Access•Clay S Bell, Timothy L Vaughn et al.•Elementa Science of the…•2020

Citation velocityhistorical
Highly citedNo

Tools

Open DOIOpen Access
Ethnos_APP • Open Source Project • MIT License • Frontend v2.0.0 • Privacy and Cookies • API Documentation: api.ethnos.app/docs • API Source Code: GitHub • DOI: 10.5281/zenodo.17049435 • Frontend Source Code: GitHub • DOI: 10.5281/zenodo.17050053 • cruz.rio.br • Expectantes Misericordiae