AuthorsGabriella da Silva Rangel Ribeiro (0000-0003-0224-5944, Universidade Federal do Rio de Janeiro), Juliana Faria Campos (0000-0001-7254-5251, Universidade Federal do Rio de Janeiro), Pedro Parreira (0000-0002-3880-6590, Escola Superior de Enfermagem de Coimbra), Rafael Celestino da Silva (0000-0002-5211-9586, Universidade Federal do Rio de Janeiro)
Year2023
Volume32
Publication date2023-01-01
Open AccessYes
TypeARTICLE
VenueTexto & Contexto - Enfermagem (JOURNAL)
Journal identifiersISSN: 0104-0707 • E-ISSN: 1980-265X
PublisherFapUNIFESP (SciELO) (PUBLISHER)
DOI10.1590/1980-265x-tce-2022-0302en
OpenAlexW4382775054
SciELOS0104-07072023000100328
LanguageEN
References cited13

Objective: to elaborate, based on the assessment of the nursing team’s flushing practice, a care technology prototype aimed at promoting good practices in intravenous catheter maintenance in intensive care. Method: a technology elaboration study, developed in three stages: flushing practice assessment through a questionnaire completed by 108 nursing professionals working in intravenous catheter maintenance in intensive care settings of a public hospital located in the city of Rio de Janeiro, Brazil. Data collection took place from November 2019 to January 2020, with descriptive and inferential data analysis; analysis of this practice regarding the existence of errors according to the main guidelines and scientific evidence, with classification of types of errors in the light of the conceptual framework of patient safety; and technology prototype development. Results: 88% of participants perform flushing in their practice; 49.5% apply the continuous pressure technique on the syringe plunger; 22% perform flushing before, between and after medication administration; predominance of use of volume and syringes with gauges of 5 ml and 10 ml. Variables related to knowledge were associated with not performing flushing. There were active and latent errors that guided the technology prototype construction. Conclusion: a care guide was built that aims to increase nursing team’s knowledge about good flushing practices and is configured as a barrier to error recurrence

Best practice · Catheter · Flushing · Health care · Intensive care · Intensive care medicine · Management · Medical emergency · Patient safety · Central Venous Catheters and Hemodialysis · Intravenous Infusion Technology and Safety · Medicine · Nursing · Patient Safety and Medication Errors · Surgery