Skip to main content

ETHNOS_APP

Home • Search • Journals • List 0

Retrospective OSL Dosimetry With Common Pharmaceuticals and Food Supplements

Bibliographic Data

ID22069142
AuthorsDaniela Ekendahl (0000-0002-5376-0797, National Radiation Protection Institute, corresponding author), Dan Reimitz (National Radiation Protection Institute)
Year2022
Volume10
Pages908016-908016
Publication date2022-06-16
Open AccessYes
TypeARTICLE
VenueFrontiers in Public Health (JOURNAL)
Journal identifiersISSN: 2296-2565 • E-ISSN: 2296-2565
PublisherFrontiers Media SA (PUBLISHER • CH)
DOI10.3389/fpubh.2022.908016
PMID35784234
OpenAlexW4282982613
LanguageEN
References cited27

Several common pharmaceuticals such as ibuprofen, paracetamol, aspirin, oral contraceptives, drugs for the prevention of motion sickness and food supplements such as table vitamins and minerals have been studied for the purposes of retrospective dosimetry using optically stimulated luminescence (OSL). The essence is that the tablets with these drug substances contain additive crystalline materials which, after irradiation and stimulation, may exhibit luminescence. For most of the pharmaceuticals and food supplements, a radiation-induced dose-dependent OSL signal was detected. Subsequently, basic dosimetric characteristics of the materials were studied, specifically sensitivity changes during repeated OSL readings, dose response, zero-dose, minimum detectable dose (MDD) and fading. The most radiation sensitive materials were food supplements with Mg providing zero-dose and MDD values at the level of several mGy. For Mg supplements, considerable sensitivity changes in OSL signal were observed. Despite this, they could be corrected using a Single-Aliquot Regenerative-dose (SAR) protocol. The OSL signals of the other materials were relatively weak but they were well reproducible and exhibited linear dose response. The MDD values were variable among the materials and ranged from 0.1 to several Gy. However, for some of the pharmaceuticals, a very high and variable zero-dose of more than 3 Gy was observed that would rule out the possibility of dose reconstruction for triage purposes. The OSL signal exhibited a significant fading rate for most of the materials. The measurements for dose reconstruction should be performed as soon as possible after irradiation, i.e. within a maximum of a few days

Dosimetry · Food irradiation · Irradiation · Nuclear medicine · Optically stimulated luminescence · Physics · Luminescence Properties of Advanced Materials · Medicine · Radiation Detection and Scintillator Technologies · Radiation Effects and Dosimetry

  • Salty Crackers as Fortuitous Dosimeters

    Open Access•Nadica Maltar-Strmečki, Nadica Maltar‐Strmečki et al.•Frontiers in Public Health•2021

Highly citedNo

Tools

Open DOIOpen Access
Ethnos_APP • Open Source Project • MIT License • Frontend v2.0.0 • Privacy and Cookies • API Documentation: api.ethnos.app/docs • API Source Code: GitHub • DOI: 10.5281/zenodo.17049435 • Frontend Source Code: GitHub • DOI: 10.5281/zenodo.17050053 • cruz.rio.br • Expectantes Misericordiae