A simplified nasopharyngeal swab collection procedure for minimizing patient discomfort while retaining sample quality
Bibliographic Data
| ID | 22076071 |
|---|---|
| Authors | Tina Uršič (0000-0002-5621-7167, University of Ljubljana, corresponding author), Rok Kogoj (0000-0002-8999-4923, University of Ljubljana), Jaka Šikonja (0000-0001-7843-8107, University of Ljubljana), Monika Jevšnik Virant (0000-0003-1754-8964, University of Ljubljana), Miroslav Petrovec (0000-0001-8498-7786, University of Ljubljana) |
| Year | 2023 |
| Volume | 11 |
| Pages | 1066934-1066934 |
| Publication date | 2023-03-23 |
| Open Access | Yes |
| Type | ARTICLE |
| Venue | Frontiers in Public Health (JOURNAL) |
| Journal identifiers | ISSN: 2296-2565 • E-ISSN: 2296-2565 |
| Publisher | Frontiers Media SA (PUBLISHER • CH) |
| DOI | 10.3389/fpubh.2023.1066934 |
| PMID | 37033037 |
| OpenAlex | W4360618993 |
| Language | EN |
| References cited | 5 |
A nasopharyngeal swab (NPS) is the most frequently collected sample type when molecular diagnosis of respiratory viruses, including SARS CoV-2, is required. An optimal collection technique would provide sufficient sample quality for the diagnostic process and would minimize the discomfort felt by the patient. This study compares a simplified NPS collection procedure with only one rotation of the swab to a more standard procedure with five rotations. Swabs were collected from 76 healthy volunteers by the same healthcare professional on 2 consecutive days at a similar hour to minimize variability. The number of Ubiquitin C copy number per sample was measured by real-time quantitative PCR and patient discomfort was assessed by questionnaire. No statistically significant difference ( p = 0.15) was observed in the Ubiquitin C copy number per sample between a NPS collected with one rotation (5.2 ± 0.6 log UBC number copies/sample) or five rotations (5.3 ± 0.5 log UBC number copies/sample). However, a statistically significant difference was observed in discomfort between these two procedures, the second being much more uncomfortable. Additional analysis of the results showed a weak correlation between discomfort and the number of human cells recovered (Spearman's rho = 0.202) and greater discomfort in younger people. The results of this study show that a NPS collected with one slow rotation has the same quality as a NPS collected with five rotations. However, the collection time is shorter and, most importantly, less unpleasant for patients
Chromatography · Data collection · Medical physics · Statistics · Airway Management and Intubation Techniques · Computer Science · Mathematics · Medicine · Radiation Dose and Imaging · Reliability and Agreement in Measurement
| Highly cited | No |
|---|