Establishment of in vitro Calibration Curve for 60Co-γ-rays Induced Phospho-53BP1 Foci, Rapid Biodosimetry and Initial Triage, and Comparative Evaluations With γH2AX and Cytogenetic Assays

Bibliographic Data

ID22079281
AuthorsRajesh Kumar Chaurasia (0000-0002-7825-2588, Bhabha Atomic Research Centre, corresponding author), Kapil B Shirsath (Bhabha Atomic Research Centre), Utkarsha N Desai (Bhabha Atomic Research Centre), Nagesh Bhat (0000-0002-3805-2100, Bhabha Atomic Research Centre, corresponding author), Nagesh N Bhat, B K Sapra (0000-0002-1666-5635, Bhabha Atomic Research Centre)
Year2022
Volume10
Pages845200-845200
Publication date2022-08-08
Open AccessYes
TypeARTICLE
VenueFrontiers in Public Health (JOURNAL)
Journal identifiersISSN: 2296-2565 • E-ISSN: 2296-2565
PublisherFrontiers Media SA (PUBLISHER • CH)
DOI10.3389/fpubh.2022.845200
PMID36003625
OpenAlexW4290546765
LanguageEN
References cited70

A rapid and reliable method for biodosimetry of populations exposed to ionizing radiation in the event of an incident or accident is crucial for initial triage and medical attention. DNA-double strand breaks (DSBs) are indicative of radiation exposure, and DSB-repair proteins (53BP1, γH2AX, ATM, etc.) are considered sensitive markers of DSB quantification. Phospho-53BP1 and γH2AX immunofluorescence technique serves as a sensitive, reliable, and reproducible tool for the detection and quantification of DSB-repair proteins, which can be used for biological dose estimations. In this study, dose-response curves were generated for 60 Co-γ-rays induced phospho-53 Binding Protein 1 (phospho-53BP1) foci at 1, 2, 4, 8, 16, and 24 h, post-irradiation for a dose range of 0.05–4 Gy using fluorescence microscopy. Following ISO recommendations, minimum detection limits (MDLs) were estimated to be 16, 18, 25, 40, 50, and 75 mGy for dose-response curves generated at 1, 2, 4, 8, 16, and 24 h post-irradiation. Colocalization and correlation of phospho-53BP1 and γH2AX were also measured in irradiated peripheral blood lymphocytes (PBLs) to gain dual confirmation. Comparative evaluation of the established curve was made by γH2AX-immunofluorescence, dicentric chromosome assay (DCA), and reciprocal translocation (RT) assays by reconstructing the dose of 6 dose-blinded samples. Coefficients of respective in-house established dose-response curves were employed to reconstruct the blind doses. Estimated doses were within the variation of 4.124%. For lower doses (0.052 Gy), phospho-53BP1 and γH2AX assays gave closer estimates with the variation of −4.1 to + 9% in comparison to cytogenetic assays, where variations were −8.5 to 24%. For higher doses (3 and 4 Gy), both the cytogenetic and immunofluorescence (phospho-53BP1 and γH2AX), assays gave comparable close estimates, with −11.3 to + 14.3% and −10.3 to −13.7%, variations, respectively

Antibody · Biodosimetry · Biology · Chromosome · Dicentric chromosome · DNA · DNA damage · Immunofluorescence · Ionizing radiation · Irradiation · Karyotype · Micronucleus test · Nijmegen breakage syndrome · Nuclear medicine · Physics · Toxicity · Carcinogens and Genotoxicity Assessment · DNA Repair Mechanisms · Effects of Radiation Exposure · Medicine · Genetics · Molecular Biology

Highly citedNo