Integration of a Ground-Based Lightning Warning System into a Mining Operation in the Democratic Republic of the Congo

Bibliographic Data

ID22331758
AuthorsAlistair D Clulow (University of KwaZulu-Natal), Alistair Clulow (0000-0001-8803-8780, University of KwaZulu-Natal), Sheldon Strydom (0000-0002-5006-2029, University of KwaZulu-Natal), Bryan Grant (University of KwaZulu-Natal), Michael J Savage (0000-0001-6108-0874, University of KwaZulu-Natal), Colin S Everson (0000-0002-9571-5249, University of KwaZulu-Natal)
Year2018
Volume10
Issue4
Pages899-912
Publication date2018-10-01
Open AccessYes
TypeARTICLE
VenueWeather, Climate, and Society (JOURNAL)
Journal identifiersISSN: 1948-8327 • E-ISSN: 1948-8335
PublisherAmerican Meteorological Society (PUBLISHER • US)
DOI10.1175/wcas-d-18-0004.1
OpenAlexW2895733604
LanguageEN
Citations received1
References cited22

Central Africa is a global lightning hot spot, with the tropical areas including the top 10 highest lightning-flash-rate densities in the world. There are no lightning-locating-system networks available across most of Africa, however, and it becomes necessary to make use of real-time, ground-based lightning early warning systems. Such a system was established in the southern Congo basin at the Kinsevere copper mine and has been operational since early 2015. The early warning system includes an electrical-field meter and a lightning-flash sensor, which produce two states of warning. Two years of data (July 2015–June 2016 and July 2016–July 2017) indicated a clear annual and daily peak in lightning activity, with an average lightning warning duration of 1.18 h and a maximum storm duration of 8.60 h. The seasonal flash occurrence was reasonably constant over the two years but was variable at a monthly level during the lightning season. Analysis of alarm state showed that the majority of events start with an escalation to an alarm state of 2 but that, over two years, 69.3% escalated further to an alarm state of 3. Alarm-duration analysis indicated that more time was spent in alarm state 3 (warning) than alarm state 2 (caution). It was concluded that a single warning state would be suitable at this location and would simplify the warning system but that appropriate alarm-activation thresholds in electric field and flash distance need further assessment

ALARM · Electrical engineering · False alarm · Geography · Lightning detection · Meteorology · Physics · Telecommunications · Thunderstorm · Warning system · Computer Science · Electrical Fault Detection and Protection · Engineering · Environmental Science · Fire effects on ecosystems · Lightning and Electromagnetic Phenomena · Artificial Intelligence

  • Assessment of a Ground-Based Lightning Detection and Near-Real-Time Warning System in the Rural Community of Swayimane, KwaZulu-Natal, South Africa

    Maqsooda Mahomed, Alistair D Clulow et al.•Weather, Climate, and Society•2021

Citations per year0.2
Citation span2021 - 2021 (1)
Highly citedNo

Tools

Open DOISci-Hub
Ethnos_APP • Open Source Project • MIT License • Frontend v2.0.0 • Privacy and Cookies • API Documentation: api.ethnos.app/docs • API Source Code: GitHub • DOI: 10.5281/zenodo.17049435 • Frontend Source Code: GitHub • DOI: 10.5281/zenodo.17050053 • cruz.rio.br • Expectantes Misericordiae