Skip to main content

ETHNOS_APP

Home • Search • Journals • List 0

Body composition of male office workers compared by means of infrared reflection measurement, bioimpedance analysis and calipermetry

Bibliographic Data

ID2991436
AuthorsChristoph Raschka, O-Sung Kwon, Horst J Koch (Vogtland-Klinik)
Year2021
Volume30
Issue2
Pages86-98
Publication date2021-12-31
Open AccessYes
TypeARTICLE
VenuePapers on Anthropology (JOURNAL)
Journal identifiersISSN: 1406-0140 • E-ISSN: 1736-7646
PublisherUniversity of Tartu (PUBLISHER • EE)
DOI10.12697/poa.2021.30.2.07
OpenAlexW4206988256
LanguageEN
Citations received1
References cited4

There are currently many different anthropometric methods to determine individual body fat percentage, as well as almost as many variants of bioelectric impedance analysis (BIA) and only a single method of infrared reflection measurement (IR) as easily feasible methods of field research. The present study aims at a simultaneous comparison between calipermetry, IR and BIA. In particular, the question which measurement method could be used as an equivalent method in the event of failure of the BIA or IR is investigated. The sample group consisted of 250 male office workers from the Rhine-Main area (average age 31.75 ± 9.16 years, average height 178.5 ± 6.93 cm and average weight 80.61 ± 9.42 kg). The measurements were previously scheduled and mostly carried out during the lunch break. For anthropometry, 13 skin fat folds were measured with the help of the Accu(R) Measure Caliper, thigh circumference with the help of a measuring tape, height with a height measuring device and body mass on the weight scale. Subsequently, an IR measurement (Futrex(R)) and a BIA (InBody(R)) were performed on the same subject. The parameters of body fat percentage and total body water (in litres) were examined. The statistical methods were correlation coefficients, Bland-Altman comparison and paired t-test for equivalence. For the men studied, the highest correlation coefficients were in the comparisons between the formulas according to Parízkova & Buzkova 1 and Parízkova & Buzkova 3 (r = 0.93), as well as for Parízkova & Buzkova 3 and Parízkova & Buzkova 4 (r = 0.96). The correlation coefficient for the IR vs. BIA comparison was only r = 0.56. A key result of the present study was the finding that certain methods cannot be substituted in an equivalent way, in fact only some calipermetric regression equations

Animal science · Anthropometry · Body mass index · Body weight · Calipers · Geometry · Hydrostatic weighing · Limits of agreement · Nuclear medicine · Pearson product-moment correlation coefficient · Statistics · Waist · Body Composition Measurement Techniques · Mathematics · Medicine · Nutrition and Health in Aging · Internal Medicine

  • Body composition of female office workers compared with infrared reflection measurement, bioimpedance analysis and calipermetry

    Open Access•Christoph Raschka, O-Sung Kwon et al.•Papers on Anthropology•2022

  • Generalized equations for predicting body density of men

    Open Access•Andrew S Jackson, M L Pollock•British Journal of Nutrition•1978

  • Measuring agreement in method comparison studies

    Open Access•John M Bland, David G Altman et al.•Statistical Methods in Medical…•1999

  • Statistical Methods for Assessing Agreement Between Two Methods of Clinical Measurement

    Open Access•J Martin Bland, DouglasG Altman•The Lancet•1986

  • Effect of diurnal variation on body composition under consideration of selected chronobiological marker systems

    Open Access•Manuela Dittmar, Christoph Raschka et al.•Anthropological Review•2002

Citations per year0.25
Citation span2022 - 2022 (1)
Highly citedNo

Tools

Open DOIOpen Access
Ethnos_APP • Open Source Project • MIT License • Frontend v2.0.0 • Privacy and Cookies • API Documentation: api.ethnos.app/docs • API Source Code: GitHub • DOI: 10.5281/zenodo.17049435 • Frontend Source Code: GitHub • DOI: 10.5281/zenodo.17050053 • cruz.rio.br • Expectantes Misericordiae