Skip to main content

ETHNOS_APP

Home • Search • Journals • List 0

Reliability of assessing skeletal muscle architecture and tissue organization of the gastrocnemius medialis and vastus lateralis muscle using ultrasound and spatial frequency analysis

Bibliographic Data

ID4681352
AuthorsMelanie Lesinski (0000-0002-5945-2998, University of Potsdam, corresponding author), Gregory Bashford, Gregory R Bashford (University of Nebraska–Lincoln), Adrian Markov (0000-0002-1855-5552, University of Potsdam), Lucie Risch (0000-0001-7519-3773, University of Potsdam), Michael Cassel (0000-0002-6947-4517, University of Potsdam)
Year2024
Volume6
Pages1282031-1282031
Publication date2024-01-18
Open AccessYes
TypeARTICLE
VenueFrontiers in Sports and Active Living (JOURNAL)
Journal identifiersISSN: 2624-9367 • E-ISSN: 2624-9367
PublisherFrontiers Media SA (PUBLISHER • CH)
DOI10.3389/fspor.2024.1282031
PMID38304420
OpenAlexW4390980900
LanguageEN
Citations received2
References cited34

IntroductionThe purpose of this study was to investigate inter- and intra-rater reliability as well as the inter-rater interpretation error of ultrasound measurements assessing skeletal muscle architecture and tissue organization of the gastrocnemius medialis (GM) and vastus lateralis (VL) muscle.MethodsThe GM and VL of 13 healthy adults (22 ± 3 years) were examined thrice with sagittal B-mode ultrasound: intraday test-retest examination by one investigator (intra-rater) and separate examinations by two investigators (inter-rater). Additionally, images from one investigator were analysed by two interpretators (interpretation error). Muscle architecture was assessed by muscle thickness [MT], fascicle length [FL], as well as superior and inferior pennation angle [PA]. Muscle tissue organization was determined by spatial frequency analysis (SFA: peak spatial frequency radius, peak −6 dB width, PSFR/P6, normalized peak value of amplitude spectrum [Amax], power within peak [PWP], peak power percent). Reliability of ultrasound examination and image interpretation are presented as intraclass correlation coefficient (ICC), test-retest variability, standard error of measurement as well as bias and limits of agreement.ResultsGM and VL demonstrated excellent ICCs for inter- and intra-rater reliability, along with excellent ICCs for interpretation error of MT (0.91-0.99), showing minimal variability (<5%) and SEM% (<5%). Systematic bias for MT was less than 1 mm. For PA and FL poor to good ICCs for inter- and intra-rater reliability were revealed (0.41-0.90), with moderate variability (<12%), low SEM% (<10%) and systematic bias between 0.1-1.4°. Tissue organization analysis indicated moderate to good ICCs for inter- and intra-rater reliability. Notably, Amax and PWP consistently held the highest ICC values (0.77-0.87) across all analyses but with higher variability (<24%) and SEM% (<18%), compared to lower variability (<9%) and SEM% (<8%) in other tissue organization parameters. Interpretation error of all muscle tissue organization parameters showed excellent ICCs (0.96-0.999) with very low variability (≤1%) and SEM% (<2%), except Amax & PWP (TRV%: <6%; SEM%: <7%).ConclusionOur findings demonstrated excellent inter- and intra-rater reliability for MT. However, agreement for PA, FL, and SFA parameters was not as strong. Additionally, MT and all SFA parameters exhibited excellent agreement for inter-rater interpretation error. Therefore, the SFA seems to offer the possibility of objectively and reliably evaluating ultrasound images

Electromyography · Fascicle · Intraclass correlation · Muscle architecture · Nuclear medicine · Physical medicine and rehabilitation · Physical therapy · Physics · Power (physics · Radiology · Reliability (semiconductor · Reproducibility · Skeletal muscle · Statistics · Ultrasound · Vastus medialis · Mathematics · Medicine · Muscle activation and electromyography studies · Sports injuries and prevention · Sports Performance and Training · Anatomy

  • Maturity-related acute effects of resistance exercise on muscle architecture and tissue organization of the resting and maximally isometrically contracted gastrocnemius medialis in girls

    Open Access•Melanie Lesinski, Luisa Walther et al.•Frontiers in Sports and Active…•2026

  • Reproducibility of freehand vs. foam cast as well as the intrarater reliability of foam cast ultrasound scans assessing the muscle architecture and tissue organization of the gastrocnemius medialis and vastus lateralis muscles

    Open Access•Melanie Lesinski, Gregory Bashford et al.•Frontiers in Sports and Active…•2024

  • Measuring agreement in method comparison studies

    Open Access•John M Bland, David G Altman et al.•Statistical Methods in Medical…•1999

  • Statistical Methods For Assessing Measurement Error (Reliability) in Variables Relevant to Sports Medicine

    Open Access•Greg Atkinson, Alan M Nevill et al.•Sports Medicine•1998

  • A Guideline of Selecting and Reporting Intraclass Correlation Coefficients for Reliability Research

    Open Access•Terry K Koo, Mae Y Li•Journal of Chiropractic Medicine•2016

Citations per year1
Citation span2024 - 2026 (3)
Highly citedNo

Tools

Open DOIOpen Access
Ethnos_APP • Open Source Project • MIT License • Frontend v2.0.0 • Privacy and Cookies • API Documentation: api.ethnos.app/docs • API Source Code: GitHub • DOI: 10.5281/zenodo.17049435 • Frontend Source Code: GitHub • DOI: 10.5281/zenodo.17050053 • cruz.rio.br • Expectantes Misericordiae