Skip to main content

ETHNOS_APP

Home • Search • Journals • List 0

Initial Evaluation of the Concept-2 Rowing Ergometer's Accuracy Using a Motorized Test Rig

Bibliographic Data

ID5284917
AuthorsGunnar Treff (0000-0001-5388-4282), Lennart Mentz (0000-0001-7017-2746), Benjamin Mayer (0000-0003-1042-9006), Kay Winkert (0000-0002-3460-2320), Thomas Engleder, Jürgen M Steinacker (0000-0001-8901-9450)
Year2022
Volume3
Pages801617-801617
Publication date2022-01-25
Open AccessYes
TypeARTICLE
VenueFrontiers in Sports and Active Living (JOURNAL)
Journal identifiersISSN: 2624-9367 • E-ISSN: 2624-9367
PublisherFrontiers Media SA (PUBLISHER • CH)
DOI10.3389/fspor.2021.801617
PMID35146423
OpenAlexW4210689860
LanguageEN
Citations received2
References cited16

IntroductionThe Concept 2 (C2) rowing ergometer is used worldwide for home-based training, official competitions, and performance assessment in sports and science. Previous studies reported a disparate underestimation of mechanical power output positively related to an unclearly defined stroke variability. The aim of this study was to quantify the accuracy of the C2 while controlling for the potentially influencing variables of the rowing stroke by using a test rig for air-braked rowing ergometers and thus excluding biological variability.MethodsA unique motorized test rig for rowing ergometers was employed. Accuracy was assessed as the difference in mechanical power output between C2 and a reference system during steady (i.e., minimal variations of stroke power within a series of 50 spacemark, no -strokes) and unsteady simulated rowing (i.e., persistent variations during measurement series) while manipulating the stroke variables shape, force, or rate.ResultsDuring steady simulated rowing, differences between C2 and the reference system ranged 2.9-4.3%. Differences were not significantly affected by stroke shapes (P = 0.153), but by stroke rates ranging 22-28 min−1 (P < 0.001). During unsteady simulated rowing with alterations of stroke force and rate, mean differences of 2.5-3.9% were similar as during steady simulated rowing, but the random error increased up to 18-fold. C2 underestimated mechanical power output of the first five strokes by 10-70%. Their exclusion reduced mean differences to 0.2-1.9%.ConclusionDue to the enormous underestimation of the start strokes, the nominal accuracy of the C2 depends on the total number of strokes considered. It ranges 0.2-1.9%, once the flywheel has been sufficiently accelerated. Inaccuracy increases with uneven rowing, but the stroke shape has a marginal impact. Hence, rowers should row as even as possible and prefer higher stroke rates to optimize C2 readings. We recommend external reference systems for scientific and high-performance assessments, especially for short tests designs where the start strokes will have a major impact

Physical medicine and rehabilitation · Physical therapy · Rowing · Simulation · Statistics · Stroke (engine · Cardiovascular and exercise physiology · Computer Science · Engineering · Mathematics · Medicine · Sport Psychology and Performance · Sports Performance and Training · Mechanical Engineering

  • The Influence of Covid-19 on University Students’ Well-Being, Physical Activity, Body Composition, and Strength Endurance

    Open Access•Robert Podstawski, Kevin J Finn et al.•International Journal of…•2022

  • Contribution of trunk swing to the performance of fixed-seat rowing

    Open Access•Renee Lafreniere, Matt Jensen et al.•Frontiers in Sports and Active…•2025

  • Measuring agreement in method comparison studies

    Open Access•John M Bland, David G Altman et al.•Statistical Methods in Medical…•1999

  • Statistical Methods for Assessing Agreement Between Two Methods of Clinical Measurement

    Open Access•J Martin Bland, DouglasG Altman•The Lancet•1986

Citations per year0.5
Citation span2022 - 2025 (4)
Highly citedNo

Tools

Open DOIOpen Access
Ethnos_APP • Open Source Project • MIT License • Frontend v2.0.0 • Privacy and Cookies • API Documentation: api.ethnos.app/docs • API Source Code: GitHub • DOI: 10.5281/zenodo.17049435 • Frontend Source Code: GitHub • DOI: 10.5281/zenodo.17050053 • cruz.rio.br • Expectantes Misericordiae