Recent advances in imaging have led to high‐resolution computerized tomography (CT) scanning with exquisitely detailed slice images of the skull and three‐dimensional (3‐D) surface reconstructions using computer software. It is possible to use CT scans to acquire morphologic information about the skull in a convenient digital form and to derive 3‐D measurements from surface reconstruction images. Unfortunately, no effort has been made to date to test the validity of these measurements on laboratory specimens, and no compelling evidence is available from phantom studies to indicate the nature and magnitude of the errors inherent in the measurement technique. We have performed a pilot study to quantify the morphology of the skull based on surface features that can be found in CT scans and 3‐D reconstructions. Comparative measurements were obtained from five skulls (two normal and three with dysmorphology) with calipers and a 3‐D electromagnetic digitizer. These measurements were statistically compared with those based on original CT scan slices and reformatted 3‐D images. It is concluded that 3D‐CT measurements techniques are superior to those in which measurements are obtained directly from the original CT slices; 3‐D CT methods, however, must be significantly improved before measurements based on these techniques can be used in studies that require a high degree of precision. The results are used to indicate the most fruitful areas of future study
Calipers · Computed tomography · Computer vision · Imaging phantom · Nuclear medicine · Optics · Physics · Radiology · Skull · Tomography · Anatomy · Anatomy and Medical Technology · Artificial Intelligence · Biomedical Engineering · Computer Science · Dental Radiography and Imaging · Medical Imaging and Analysis · Medicine
The Suitability of 3D Data
Validation Study of Discriminating Sex using the Atlas from the Digital Korean 3D Human Body Modeling
Midfacial growth patterns in males from newborn to 5 years old based on computed tomography
Evaluation of the reliability and accuracy of femur measurements acquired from computed tomography images
Standard methods for creating digital skeletal models using structure‐from‐motion photogrammetry
Sex and stature estimation on the tibia
Comparison of coordinate measurement precision of different landmark types on human crania using a 3D laser scanner and a 3D digitiser
Evaluating the Consistency, Repeatability, and Reproducibility of Osteometric Data on Dry Bone Surfaces, Scanned Dry Bone Surfaces, and Scanned Bone Surfaces Obtained from Living Individuals
| Unique citing works | 8 |
|---|---|
| Citations per year | 0,53 |
| Citation span | 2011 - 2024 (14) |
| Citation velocity | recent |
| Highly cited | No |
| Citation types | Neutral: 8 |