Rosaria Falsaperla
Biographic Data
| ID | 7902233 |
|---|---|
| NAME | Rosaria Falsaperla |
| GIVEN NAMES | Rosaria |
| FAMILY NAME | Falsaperla |
| SIGNATURE | FALSAPERLA R |
| AFFILIATIONS | Istituto Nazionale per l'Assicurazione Contro gli Infortuni sul Lavoro |
| VERIFIED | No |
| TOTAL WORKS | 4 |
| TOTAL CITATIONS | 0 |
| WORKS AS AUTHOR | 4 |
| WORKS AS EDITOR | 0 |
| FIRST PUBLICATION YEAR | 2021 |
| LATEST PUBLICATION YEAR | 2026 |
| H-INDEX | 0 |
Intersubject variability in a comprehensive numerical assessment of operator electromagnetic exposure to TMS
Introduction: Transcranial magnetic stimulation (TMS) is increasingly used in clinical and research settings, often requiring the operator to remain in close proximity to the stimulation coil. While regulatory guidelines exist for patient safety, the workplace exposure assessment, particularly its dependence on operator anatomy, remains limited. This study aimed to comprehensively evaluate the electric field (E-field) induced in TMS operators und…
Results of a national survey among occupational physicians to estimate the number of workers with active medical devices and their types in the context of managing electromagnetic hazards
Introduction: Occupational exposure to electromagnetic fields (EMF) is almost ubiquitous: workers with Active Implantable Medical Devices (AIMD) and Active Wearable Medical Devices (AWMD) are considered at particular risk with respect to occupational risk assessment and health surveillance (HS) procedures, due to possible electromagnetic hazards resulting in interference problems. The identification of these workers is therefore fundamental for p…
Issues in the Implementation of Directive 2013/35/EU Regarding the Protection of Workers against Electromagnetic Fields
In 2016 the Directive 2013/35/EU regarding the protection of health and safety of workers exposed to electromagnetic fields was transposed in Italy. Since then, the authors of this paper have been faced with several issues related to the implementation of the provisions of the Directive, which pose some interpretative and operative concerns. A primary critical feature of the Directive is that, in some circumstances, conditions of "overexposure", …
Workers with Cardiac Aimd Exposed to EMF
Workers with cardiac active implantable medical devices (AIMD), such as a pacemaker (PM) or an implantable defibrillator (ICD), are considered by the occupational health and safety regulation framework as a particularly sensitive risk group that must be protected against the dangers caused by the interference of electromagnetic field (EMF). In this paper, we first describe the general methodology that shall be followed for the risk assessment of …
No prominent works on this page.
Issues in the Implementation of Directive 2013/35/EU Regarding the Protection of Workers against Electromagnetic Fields
In 2016 the Directive 2013/35/EU regarding the protection of health and safety of workers exposed to electromagnetic fields was transposed in Italy. Since then, the authors of this paper have been faced with several issues related to the implementation of the provisions of the Directive, which pose some interpretative and operative concerns. A primary critical feature of the Directive is that, in some circumstances, conditions of "overexposure", …
Workers with Cardiac Aimd Exposed to EMF
Workers with cardiac active implantable medical devices (AIMD), such as a pacemaker (PM) or an implantable defibrillator (ICD), are considered by the occupational health and safety regulation framework as a particularly sensitive risk group that must be protected against the dangers caused by the interference of electromagnetic field (EMF). In this paper, we first describe the general methodology that shall be followed for the risk assessment of …
Results of a national survey among occupational physicians to estimate the number of workers with active medical devices and their types in the context of managing electromagnetic hazards
Introduction: Occupational exposure to electromagnetic fields (EMF) is almost ubiquitous: workers with Active Implantable Medical Devices (AIMD) and Active Wearable Medical Devices (AWMD) are considered at particular risk with respect to occupational risk assessment and health surveillance (HS) procedures, due to possible electromagnetic hazards resulting in interference problems. The identification of these workers is therefore fundamental for p…
Intersubject variability in a comprehensive numerical assessment of operator electromagnetic exposure to TMS
Introduction: Transcranial magnetic stimulation (TMS) is increasingly used in clinical and research settings, often requiring the operator to remain in close proximity to the stimulation coil. While regulatory guidelines exist for patient safety, the workplace exposure assessment, particularly its dependence on operator anatomy, remains limited. This study aimed to comprehensively evaluate the electric field (E-field) induced in TMS operators und…
Electromagnetic Fields and Biological Effects (3 works) · Medicine (3 works) · Business (2 works) · Computer Science (2 works) · Environmental health (2 works) · Quality and Safety in Healthcare (2 works) · Cardiac pacing and defibrillation studies (1 work) · Clinical Practice (1 work) · Computer security (1 work) · Directive (1 work)