Skip to main content

ETHNOS_APP

Home • Search • Journals • List 0

Intersubject variability in a comprehensive numerical assessment of operator electromagnetic exposure to TMS

Bibliographic Data

ID22083702
AuthorsSimona D’Agostino (0000-0002-5605-760X, Sapienza University of Rome), M Colella (Sapienza University of Rome), Rosaria Falsaperla (Istituto Nazionale per l'Assicurazione Contro gli Infortuni sul Lavoro), M Liberti (Sapienza University of Rome), F Apollonio (Sapienza University of Rome, corresponding author)
Year2026
Volume13
Pages1705893-1705893
Publication date2026-02-02
Open AccessYes
TypeARTICLE
VenueFrontiers in Public Health (JOURNAL)
Journal identifiersISSN: 2296-2565 • E-ISSN: 2296-2565
PublisherFrontiers Media SA (PUBLISHER • CH)
DOI10.3389/fpubh.2025.1705893
PMID41704283
OpenAlexW7127166875
LanguageEN
References cited54

Introduction: Transcranial magnetic stimulation (TMS) is increasingly used in clinical and research settings, often requiring the operator to remain in close proximity to the stimulation coil. While regulatory guidelines exist for patient safety, the workplace exposure assessment, particularly its dependence on operator anatomy, remains limited. This study aimed to comprehensively evaluate the electric field (E-field) induced in TMS operators under realistic working conditions, with a focus on how inter-subject anatomical variability affects compliance with international safety guidelines. Methods: Numerical simulations were performed using four anatomically detailed virtual human models exposed to a circular TMS coil in clinically relevant positions. Two coil heights (chest and abdomen) and three coil-to-operator distances (12 cm, 22 cm, 40 cm) were analyzed. The induced E-field was computed using magneto-quasi-static solvers, and the results were compared with the ICNIRP basic restriction for occupational exposure (1.13 V/m) and with the experimental threshold for peripheral neurostimulation (4 V/m). Whole-body percentiles, localized distributions, and anatomical cross-sections were evaluated to characterize inter-subject variability. Results: At 40 cm, all models and exposure scenarios were compliant with ICNIRP limits. At 22 cm, most configurations remained compliant, though some models slightly exceeded the reference level, particularly in the abdominal region. At 12 cm, the induced E-field systematically exceeded the occupational limit across all models, while remaining below the neurostimulation threshold. Anatomical features, such as subcutaneous adipose tissue thickness and tissue discontinuities, were found to strongly influence field localization and intensity, especially at closer distances. Conclusion: Operator exposure to TMS is influenced by both coil positioning and individual anatomical characteristics. While increasing distance ensures compliance and reduces variability, closer configurations may require tailored assessments or mitigation strategies. These findings highlight the importance of considering inter-subject variability in the evaluation of operator exposure and suggest that anatomical models may underestimate variability in real clinical contexts. A limitation of this study is the assumption of a static operator not manually holding the coil, a common condition in clinical practice that warrants further investigation

Clinical Practice · Electromagnetic coil · Electromagnetic Fields and Biological Effects · Muscle activation and electromyography studies · Transcranial Magnetic Stimulation Studies

  • Neurocognitive Effects of Repetitive Transcranial Magnetic Stimulation in Adolescents with Major Depressive Disorder

    Open Access•Christopher A Wall, Paul E Croarkin et al.•Frontiers in Psychiatry•2013

  • Evaluation of Peripheral Electrostimulation Thresholds in Human Model for Uniform Magnetic Field Exposure

    Open Access•Yosuke Suzuki, José Gómez-Tames et al.•International Journal of…•2021

  • Human Exposure Assessment to Wearable Antennas

    Open Access•Silvia Gallucci, Marta Bonato et al.•International Journal of…•2022

Highly citedNo

Tools

Open DOIOpen Access
Ethnos_APP • Open Source Project • MIT License • Frontend v2.0.0 • Privacy and Cookies • API Documentation: api.ethnos.app/docs • API Source Code: GitHub • DOI: 10.5281/zenodo.17049435 • Frontend Source Code: GitHub • DOI: 10.5281/zenodo.17050053 • cruz.rio.br • Expectantes Misericordiae