Skip to main content

ETHNOS_APP

Home • Search • Journals • List 0

Effect of Different Implant Designs on Strain and Stress Distribution under Non-Axial Loading

A Three-Dimensional Finite Element Analysis

Bibliographic Data

ID15475620
AuthorsHelder Oliveira (0000-0003-2821-1929, Fernando Pessoa University), Aritza Brizuela‐Velasco (0000-0001-6421-3863, Universidad de Oviedo), Aritza Brizuela Velasco (Universidad de Oviedo), JV Ríos-Santos (0000-0002-8121-6166, Universidad de Sevilla, corresponding author), Fernando Sánchez Lasheras (0000-0002-7052-2811, Universidad de Oviedo), Bernardo Ferreira Lemos (0000-0002-9896-5139, Fernando Pessoa University), F J Gil (0000-0003-3265-5071, Universitat Internacional de Catalunya), Alexandrine Carvalho (Fernando Pessoa University), Mariano Herrero‐Climent (0000-0003-3284-1528, Instituto Português de Oncologia Francisco Gentil), Mariano Herrero-Climent (Porto Dental Institute, 4150-518 Oporto, Portugal)
Year2020
Volume17
Issue13
Pages4738-4738
Publication date2020-07-01
Open AccessYes
TypeARTICLE
VenueInternational Journal of Environmental Research and Public Health (JOURNAL)
Journal identifiersISSN: 1661-7827 • E-ISSN: 1660-4601
PublisherMultidisciplinary Digital Publishing Institute (PUBLISHER • CH)
DOI10.3390/ijerph17134738
PMID32630294
OpenAlexW3038976111
LanguageEN
References cited36

Implant design evolved alongside the development of implant therapy. The purpose of this finite element analysis (FEA) study was to analyze the influence of different implant designs on the stress and strain distribution to the implants and surrounding bone. Three implant designs with the same length and diameter were used. The three-dimensional geometry of the bone was simulated with a cortical bone of three different thicknesses and two medullar bone densities: low density (150 Hounsfield units) and high density (850 Hounsfield units). A 30° oblique load of 150 N was applied to the implant restoration. Displacement and stress (von Mises) results were obtained for bone and dental implants. The strain and stress distributions to the bone were higher for the tissue-level implant for all types of bone. The maximum principal strain and stress decreased with an increase in cortical bone thickness for both cancellous bone densities. The distribution of the load was concentrated at the coronal portion of the bone and implants. All implants showed a good distribution of forces for non-axial loads, with higher forces concentrated at the crestal region of the bone-implant interface. Decrease in medullar bone density negatively affects the strain and stress produced by the implants

Bone density · Cancellous bone · Composite material · Computed tomography · Coronal plane · Cortical bone · Deformation (meteorology · Displacement (psychology · Finite element method · Hounsfield scale · Implant · Osteoporosis · Stress (linguistics · Stress–strain curve · Structural engineering · von Mises yield criterion · Bone Tissue Engineering Materials · Dental Implant Techniques and Outcomes · Dentistry · Engineering · Materials Science · Medicine · Orthopaedic implants and arthroplasty · Anatomy · Biomedical Engineering · Surgery

Highly citedNo

Tools

Open DOIOpen Access
Ethnos_APP • Open Source Project • MIT License • Frontend v2.0.0 • Privacy and Cookies • API Documentation: api.ethnos.app/docs • API Source Code: GitHub • DOI: 10.5281/zenodo.17049435 • Frontend Source Code: GitHub • DOI: 10.5281/zenodo.17050053 • cruz.rio.br • Expectantes Misericordiae