JV Ríos-Santos
Biographic Data
| ID | 7861434 |
|---|---|
| NAME | JV Ríos-Santos |
| GIVEN NAMES | JV |
| FAMILY NAME | Ríos-Santos |
| SIGNATURE | RÍOS-SANTOS J |
| AFFILIATIONS | Universidad de Sevilla |
| ORCID | 0000-0002-8121-6166 |
| VERIFIED | Yes |
| TOTAL WORKS | 7 |
| TOTAL CITATIONS | 0 |
| WORKS AS AUTHOR | 7 |
| WORKS AS EDITOR | 0 |
| FIRST PUBLICATION YEAR | 2020 |
| LATEST PUBLICATION YEAR | 2022 |
| H-INDEX | 0 |
Incidence of Peri-Implantitis and Relationship with Different Conditions
Articles on the prevalence of peri-implant diseases showed that 90% of peri-implant tissues had some form of inflammatory response and a prevalence of peri-implantitis from 28% to 51% according to various publications. Objective: To provide an overview of how risk factors can be related with peri-implantitis. Methods: A retrospective longitudinal study including 555 implants placed in 132 patients was evaluated based on the presence of peri-impla…
Influence of Removing or Leaving the Prosthesis after Regenerative Surgery in Peri-Implant Defects
There are no statistically significant differences in the response to treatment when removing or keeping the prosthesis after regenerative surgery in peri-implant defects
Assessment of the Simultaneous Use of Biomaterials in Transalveolar Sinus Floor Elevation
Implants inserted in the posterior maxilla frequently need additional surgery for successful bone augmentation. One of the most common procedures for this is transalveolar sinus floor elevation. There are different protocols for this procedure, and there is controversy over the simultaneous application of grafting material upon elevating. In this prospective randomized clinical study in humans, a total of 49 transalveolar sinus floor elevations w…
Influence of the CAD-CAM Systems on the Marginal Accuracy and Mechanical Properties of Dental Restorations
The aim of this study was to compare the quality of different computer-assisted-design and computer assisted manufacturing systems (CAD-CAM) generated by only one scanner, focusing on vertical fit discrepancies and the mechanical properties. A master model was obtained from a real clinical situation: the replacement of an absent (pontic) tooth, with the construction of a fixed partial denture on natural abutments with three elements. Nine scans w…
Influence of Implant Design and Under-Preparation of the Implant Site on Implant Primary Stability. An In Vitro Study
The aim of this study was to evaluate the effects of different implant sites an under-preparation sequence associated with two different implant designs on implant primary stability measured by two parameters: insertion torque (IT) and implant stability quotient (ISQ). It used two different implants: one cylindrical as a control and another one with a tapered design. The implants were inserted in type III fresh humid bovine bone and four drilling…
Improvement of Periodontal Parameters with the Sole Use of Free Gingival Grafts in Orthodontic Patients
Augmentation of the width of keratinized gingiva; as the sole treatment; favors the improvement of GI and PI during orthodontic therapy
Effect of Different Implant Designs on Strain and Stress Distribution under Non-Axial Loading
Implant design evolved alongside the development of implant therapy. The purpose of this finite element analysis (FEA) study was to analyze the influence of different implant designs on the stress and strain distribution to the implants and surrounding bone. Three implant designs with the same length and diameter were used. The three-dimensional geometry of the bone was simulated with a cortical bone of three different thicknesses and two medulla…
No prominent works on this page.
Assessment of the Simultaneous Use of Biomaterials in Transalveolar Sinus Floor Elevation
Implants inserted in the posterior maxilla frequently need additional surgery for successful bone augmentation. One of the most common procedures for this is transalveolar sinus floor elevation. There are different protocols for this procedure, and there is controversy over the simultaneous application of grafting material upon elevating. In this prospective randomized clinical study in humans, a total of 49 transalveolar sinus floor elevations w…
Influence of the CAD-CAM Systems on the Marginal Accuracy and Mechanical Properties of Dental Restorations
The aim of this study was to compare the quality of different computer-assisted-design and computer assisted manufacturing systems (CAD-CAM) generated by only one scanner, focusing on vertical fit discrepancies and the mechanical properties. A master model was obtained from a real clinical situation: the replacement of an absent (pontic) tooth, with the construction of a fixed partial denture on natural abutments with three elements. Nine scans w…
Influence of Implant Design and Under-Preparation of the Implant Site on Implant Primary Stability. An In Vitro Study
The aim of this study was to evaluate the effects of different implant sites an under-preparation sequence associated with two different implant designs on implant primary stability measured by two parameters: insertion torque (IT) and implant stability quotient (ISQ). It used two different implants: one cylindrical as a control and another one with a tapered design. The implants were inserted in type III fresh humid bovine bone and four drilling…
Improvement of Periodontal Parameters with the Sole Use of Free Gingival Grafts in Orthodontic Patients
Augmentation of the width of keratinized gingiva; as the sole treatment; favors the improvement of GI and PI during orthodontic therapy
Effect of Different Implant Designs on Strain and Stress Distribution under Non-Axial Loading
Implant design evolved alongside the development of implant therapy. The purpose of this finite element analysis (FEA) study was to analyze the influence of different implant designs on the stress and strain distribution to the implants and surrounding bone. Three implant designs with the same length and diameter were used. The three-dimensional geometry of the bone was simulated with a cortical bone of three different thicknesses and two medulla…
Influence of Removing or Leaving the Prosthesis after Regenerative Surgery in Peri-Implant Defects
There are no statistically significant differences in the response to treatment when removing or keeping the prosthesis after regenerative surgery in peri-implant defects
Incidence of Peri-Implantitis and Relationship with Different Conditions
Articles on the prevalence of peri-implant diseases showed that 90% of peri-implant tissues had some form of inflammatory response and a prevalence of peri-implantitis from 28% to 51% according to various publications. Objective: To provide an overview of how risk factors can be related with peri-implantitis. Methods: A retrospective longitudinal study including 555 implants placed in 132 patients was evaluated based on the presence of peri-impla…
Medicine (7 works) · Dental Implant Techniques and Outcomes (6 works) · Dentistry (6 works) · Surgery (5 works) · Implant (4 works) · Periodontal Regeneration and Treatments (4 works) · Materials Science (3 works) · Biomedical Engineering (2 works) · Composite material (2 works) · Dental materials and restorations (2 works)