Skip to main content

ETHNOS_APP

Home • Search • Journals • List 0

Influence of Implant Design and Under-Preparation of the Implant Site on Implant Primary Stability. An In Vitro Study

Bibliographic Data

ID15478682
AuthorsMariano Herrero‐Climent (0000-0003-3284-1528), Mariano Herrero-Climent (Porto Dental Institute, 4150-518 Porto, Portugal), Bernardo Ferreira Lemos (0000-0002-9896-5139, Fernando Pessoa University), Federico Herrero‐Climent (Universidad Complutense de Madrid), Federico Herrero-Climent (Department of Periodontology, University Complutense of Madrid, 28040 Madrid, Spain), Carlos Falcão (0000-0001-8031-6176, Fernando Pessoa University), Helder Oliveira (0000-0003-2821-1929, Fernando Pessoa University), Manuela Herrera Martínez (0000-0003-1624-4096, Universidad de Sevilla), Manuela Herrera (Universidad de Sevilla), F J Gil (0000-0003-3265-5071, Universitat Internacional de Catalunya), Blanca Ríos‐Carrasco (0000-0002-2832-5902, Universidad de Sevilla), JV Ríos-Santos (0000-0002-8121-6166, Universidad de Sevilla, corresponding author)
Year2020
Volume17
Issue12
Pages4436-4436
Publication date2020-06-20
Open AccessYes
TypeARTICLE
VenueInternational Journal of Environmental Research and Public Health (JOURNAL)
Journal identifiersISSN: 1661-7827 • E-ISSN: 1660-4601
PublisherMultidisciplinary Digital Publishing Institute (PUBLISHER • CH)
DOI10.3390/ijerph17124436
PMID32575702
OpenAlexW3035919271
LanguageEN
References cited42

The aim of this study was to evaluate the effects of different implant sites an under-preparation sequence associated with two different implant designs on implant primary stability measured by two parameters: insertion torque (IT) and implant stability quotient (ISQ). It used two different implants: one cylindrical as a control and another one with a tapered design. The implants were inserted in type III fresh humid bovine bone and four drilling sequences were used: one control, the one proposed by the implant company (P1), and three different undersized (P2, P3 and P4). P2 was the same as P1 without the cortical drill, P3 was without the last pilot drill and P4 was without both of them. The sample size was n = 40 for each of the eight groups. Final IT was measured with a torquemeter and the ISQ was measured with Penguin resonance frequency analysis. Results showed that both ISQ and IT have a tendency to increase as the preparation technique reduces the implant site diameter when compared with the standard preparation, P1. The preparations without cortical drill, P2 and P4, showed the best results when compared with the ones with a cortical drill. Tapered implants always showed higher or the same ISQ and IT values when compared with the cylindrical implants. Giving the limitations of this study, it can be concluded that reducing implant preparation can increase IT and ISQ values. Removing the cortical drill and the use of a tapered design implant are also effective methods of increasing primary implant stability

Drill · Implant · Implant stability quotient · Osseointegration · Resonance frequency analysis · Dental Implant Techniques and Outcomes · Dental materials and restorations · Dentistry · Materials Science · Medicine · Orthopaedic implants and arthroplasty · Biomedical Engineering · Surgery

Highly citedNo

Tools

Open DOIOpen Access
Ethnos_APP • Open Source Project • MIT License • Frontend v2.0.0 • Privacy and Cookies • API Documentation: api.ethnos.app/docs • API Source Code: GitHub • DOI: 10.5281/zenodo.17049435 • Frontend Source Code: GitHub • DOI: 10.5281/zenodo.17050053 • cruz.rio.br • Expectantes Misericordiae